Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000871

Tests4
Approved1
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-20 09:02 83894 639228133388127528-4927 S0003591 Fail View
2026-08-20 09:04 83895 639228134300853745-1946 S0003591 Fail View
2026-08-20 09:06 83896 639228135561357359-1765 S0003591 Fail View
2026-08-20 09:16 83901 639228141308629405-8552 S0003591 Pass View

Test 83895

Result
Fail
Date
2026-08-20 09:04
Article
S0003591
ID record
639228134300853745-1946
ID production
Temperature
Humidity
Test duration
15
Error ID
208
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5594.00186 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1000.84829 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.738279927 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.913392815 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1354558.56 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.17401696 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29128363 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28345241 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.28140894 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79638335 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9870233 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0125206 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 12.0234206 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-08-20 09:02 1000.882 950 1050
2026-08-20 09:04 1000.848 950 1050
2026-08-20 09:06 1000.851 950 1050
2026-08-20 09:16 1000.864 950 1050