Serial lookup
Search a serial number to see its full test history.
Serial C00000822
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-08-20 06:56 | 83836 | 639228057318952058-3398 | S0003591 | Fail | View |
| 2026-08-20 06:57 | 83837 | 639228057711115592-3384 | S0003591 | Pass | View |
Test 83836
- Result
- Fail
- Date
- 2026-08-20 06:56
- Article
- S0003591
- ID record
- 639228057318952058-3398
- ID production
- Temperature
- Humidity
- Test duration
- 30
- Error ID
- 284
- Error text
- TestSW: [PC11] přečti log 0
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 999.477287 | 950 | 1050 | Pass |
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5585.89917 | 5320 | 5880 | Pass |
| 1.2.1 | DMM: Měření odporu: F1 (TP9/TP8) | 0.69339246 | < | 2 | Pass |
| 1.2.2 | DMM: Měření odporu: F2 (TP10/TP11) | 0.93628335 | < | 2.5 | Pass |
| 1.2.3 | DMM: Měření odporu: R3+R4 (TP10/TP8) | 689250.985 | 120000 | 1540000 | Pass |
| 2.2.1 | DMM: Měření napětí: +5V StepDown Output (TP2/TP13) | 5.15884973 | 4 | 6 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) | 3.29690596 | 2.64 | 3.96 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) | 3.29013097 | 2.64 | 3.96 | Pass |
| 2.2.4 | DMM: Měření napětí: +3V3 VDDA (TP2/TP22) | 3.29550853 | 2.64 | 3.96 | Pass |
| 2.2.5 | DMM: Měření napětí: +1V8 Audio (TP2/TP24) | 1.79767631 | 1.44 | 2.16 | Pass |
| 2.2.6 | DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) | 11.9935874 | 9.6 | 14.4 | Pass |
| 2.3.2 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.9810353 | 11.4 | 12.6 | Pass |
| 2.3.1 | AC1: Měření proudu: Kontrola odběru | 0.0214436 | < | 0.12 | Pass |
| 3.2.1 | DMM: Měření frekvence: 1kHz (TP2/TP17) | 1000.01079 | 999.8 | 1000.2 | Pass |
| 3.3.1 | DMM: Měření proudu: LEDR (TP25/TP27) | 5.64991221E-08 | < | 0.0005 | Pass |
| 3.3.2 | DMM: Měření proudu: LEDR (TP25/TP27) | 0.0349746022 | 0.015 | 0.05 | Pass |
| 3.3.3 | DMM: Měření proudu: LEDR (TP25/TP27) | 4.1228483E-07 | < | 0.0005 | Pass |
| 3.3.4 | DMM: Měření proudu: LEDG (TP25/TP27) | 5.32002853E-08 | < | 0.0005 | Pass |
| 3.3.5 | DMM: Měření proudu: LEDG (TP25/TP27) | 0.0348247363 | 0.015 | 0.05 | Pass |
| 3.3.6 | DMM: Měření proudu: LEDG (TP25/TP27) | 2.14163396E-08 | < | 0.0005 | Pass |
| 3.4.1 | DMM: Měření proudu: (TP29/TP27) | 0.000981710678 | < | 0.0013 | Pass |
| 3.4.2 | DMM: Měření proudu: (TP34/TP27) | 0.000981167809 | < | 0.0013 | Pass |
| 3.5.1 | NZ3.1: Měření proudu: Kontrola odběru | 0.00522604 | < | 0.01 | Pass |
| 3.5.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.0001645642 | < | 0.01 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-08-20 06:56 | 999.477 | 950 | 1050 |
| 2026-08-20 06:57 | 999.423 | 950 | 1050 |