Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000681

Tests4
Approved2
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-19 06:54 83176 639227192408944486-3497 S0003591 Pass View
2026-08-19 07:04 83190 639227198830047456-1705 S0003591 Fail View
2026-08-19 07:06 83192 639227199655404284-4257 S0003591 Fail View
2026-08-19 07:11 83195 639227202252928570-4035 S0003591 Pass View

Test 83192

Result
Fail
Date
2026-08-19 07:06
Article
S0003591
ID record
639227199655404284-4257
ID production
Temperature
Humidity
Test duration
40
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5611.34443 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1000.30463 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.71372401 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.686080014 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1383729.17 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.13318019 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29165032 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28519686 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.29025292 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79917781 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9923175 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0201307 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9219406 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-08-19 06:54 1000.333 950 1050
2026-08-19 07:04 1000.289 950 1050
2026-08-19 07:06 1000.305 950 1050
2026-08-19 07:11 1000.295 950 1050