Serial lookup
Search a serial number to see its full test history.
Serial C00000621
Tests8
Approved2
Failures6
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-08-19 06:26 | 83153 | 639227175369384588-1364 | S0003591 | Fail | View |
| 2026-08-19 06:26 | 83155 | 639227176040523208-5327 | S0003591 | Fail | View |
| 2026-08-19 06:27 | 83156 | 639227176501090001-6393 | S0003591 | Fail | View |
| 2026-08-19 06:34 | 83158 | 639227180238078612-3801 | S0003591 | Fail | View |
| 2026-08-19 06:35 | 83159 | 639227181246700358-6454 | S0003591 | Fail | View |
| 2026-08-19 06:47 | 83167 | 639227187748856321-9256 | S0003591 | Pass | View |
| 2026-08-19 06:57 | 83180 | 639227194218796615-5875 | S0003591 | Fail | View |
| 2026-08-19 06:59 | 83182 | 639227195028486298-8172 | S0003591 | Pass | View |
Test 83156
- Result
- Fail
- Date
- 2026-08-19 06:27
- Article
- S0003591
- ID record
- 639227176501090001-6393
- ID production
- Temperature
- Humidity
- Test duration
- 26
- Error ID
- 218
- Error text
- TestSW: test oscilátoru ON
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5579.6782 | 5320 | 5880 | Pass |
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 1000.26406 | 950 | 1050 | Pass |
| 1.2.1 | DMM: Měření odporu: F1 (TP9/TP8) | 0.699599125 | < | 2 | Pass |
| 1.2.2 | DMM: Měření odporu: F2 (TP10/TP11) | 0.801322722 | < | 2.5 | Pass |
| 1.2.3 | DMM: Měření odporu: R3+R4 (TP10/TP8) | 1407594.25 | 120000 | 1540000 | Pass |
| 2.2.1 | DMM: Měření napětí: +5V StepDown Output (TP2/TP13) | 5.14058229 | 4 | 6 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) | 3.29102099 | 2.64 | 3.96 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) | 3.28462821 | 2.64 | 3.96 | Pass |
| 2.2.4 | DMM: Měření napětí: +3V3 VDDA (TP2/TP22) | 3.28982772 | 2.64 | 3.96 | Pass |
| 2.2.5 | DMM: Měření napětí: +1V8 Audio (TP2/TP24) | 1.79673521 | 1.44 | 2.16 | Pass |
| 2.2.6 | DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) | 11.9967388 | 9.6 | 14.4 | Pass |
| 2.3.1 | AC1: Měření proudu: Kontrola odběru | 0.0204154 | < | 0.12 | Pass |
| 2.3.2 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 12.0563558 | 11.4 | 12.6 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (8)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-08-19 06:26 | 1000.24 | 950 | 1050 |
| 2026-08-19 06:26 | 1000.256 | 950 | 1050 |
| 2026-08-19 06:27 | 1000.264 | 950 | 1050 |
| 2026-08-19 06:34 | 1000.283 | 950 | 1050 |
| 2026-08-19 06:35 | 1000.27 | 950 | 1050 |
| 2026-08-19 06:47 | 1000.29 | 950 | 1050 |
| 2026-08-19 06:57 | 1000.244 | 950 | 1050 |
| 2026-08-19 06:59 | 1000.22 | 950 | 1050 |