Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000623

Tests4
Approved2
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-19 06:19 83143 639227171487655529-5681 S0003591 Pass View
2026-08-19 06:20 83145 639227172267710563-7251 S0003591 Fail View
2026-08-19 06:21 83147 639227172693058379-9690 S0003591 Fail View
2026-08-19 06:22 83148 639227173308437669-7088 S0003591 Pass View

Test 83147

Result
Fail
Date
2026-08-19 06:21
Article
S0003591
ID record
639227172693058379-9690
ID production
Temperature
Humidity
Test duration
39
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5621.00118 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 998.94407 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.766843475 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.650752032 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1395363.09 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.14324293 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.2967162 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.29033664 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.29537955 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79618739 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9879417 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0220394 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9801952 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-08-19 06:19 998.986 950 1050
2026-08-19 06:20 998.938 950 1050
2026-08-19 06:21 998.944 950 1050
2026-08-19 06:22 998.963 950 1050