Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000609

Tests3
Approved2
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-18 12:25 83046 639226526902026183-5434 S0003591 Pass View
2026-08-18 12:26 83047 639226527626518947-7965 S0003591 Fail View
2026-08-18 12:27 83048 639226528058214348-1749 S0003591 Pass View

Test 83047

Result
Fail
Date
2026-08-18 12:26
Article
S0003591
ID record
639226527626518947-7965
ID production
Temperature
Humidity
Test duration
16
Error ID
208
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5589.73846 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 999.56902 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.469310771 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.685718253 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1395520.5 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.16019054 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.28145122 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.27371148 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.25813773 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79943134 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9679997 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.00922204 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9299901 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-08-18 12:25 999.62 950 1050
2026-08-18 12:26 999.569 950 1050
2026-08-18 12:27 999.587 950 1050