Serial C00000614

Tests4
Approved2
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-18 12:04 83029 639226514337822419-8511 S0003591 Fail View
2026-08-18 12:05 83030 639226514751718900-5867 S0003591 Pass View
2026-08-18 12:06 83031 639226515573308924-9233 S0003591 Fail View
2026-08-18 12:07 83032 639226516071447381-5383 S0003591 Pass View

Test 83031

Result
Fail
Date
2026-08-18 12:06
Article
S0003591
ID record
639226515573308924-9233
ID production
Temperature
Humidity
Test duration
16
Error ID
208
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5606.7131 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 999.187901 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.708331564 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.927386142 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1389286.99 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.20128651 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.2914338 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28369029 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.26825308 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79952075 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9869413 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.00780195 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 12.0036077 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-08-18 12:04 999.27 950 1050
2026-08-18 12:05 999.227 950 1050
2026-08-18 12:06 999.188 950 1050
2026-08-18 12:07 999.213 950 1050