Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000584

Tests3
Approved2
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-18 08:17 82847 639226378226197835-3491 S0003591 Pass View
2026-08-18 08:18 82848 639226379047842991-1088 S0003591 Fail View
2026-08-18 08:20 82849 639226379647667857-7229 S0003591 Pass View

Test 82848

Result
Fail
Date
2026-08-18 08:18
Article
S0003591
ID record
639226379047842991-1088
ID production
Temperature
Humidity
Test duration
16
Error ID
208
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5602.7834 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 998.885624 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.700867772 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.706921808 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1394745.82 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.20346737 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.28714307 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.27924117 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.2638279 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.80105427 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.988614 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0123248 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9953456 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-08-18 08:17 998.959 950 1050
2026-08-18 08:18 998.886 950 1050
2026-08-18 08:20 998.863 950 1050