Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000587

Tests4
Approved2
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-18 08:06 82843 639226371878616166-6521 S0003591 Fail View
2026-08-18 08:13 82844 639226375591911838-2074 S0003591 Pass View
2026-08-18 08:21 82851 639226380443109605-7298 S0003591 Fail View
2026-08-18 08:22 82853 639226381246291890-1725 S0003591 Pass View

Test 82843

Result
Fail
Date
2026-08-18 08:06
Article
S0003591
ID record
639226371878616166-6521
ID production
Temperature
Humidity
Test duration
25
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5595.22925 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 998.146498 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.708917665 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.701456965 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 689346.075 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.13386853 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29412623 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28736762 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.29266637 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79922112 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9873464 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0115129 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 12.0013876 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-08-18 08:06 998.146 950 1050
2026-08-18 08:13 998.074 950 1050
2026-08-18 08:21 998.148 950 1050
2026-08-18 08:22 998.066 950 1050