Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000710

Tests9
Approved0
Failures9

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-18 07:27 82819 639226348538071123-3129 S0003591 Fail View
2026-08-18 07:28 82820 639226348871085838-3418 S0003591 Fail View
2026-08-18 07:30 82821 639226349932113817-3667 S0003591 Fail View
2026-08-18 07:32 82822 639226350863664117-8841 S0003591 Fail View
2026-08-18 07:32 82823 639226351409693518-9957 S0003591 Fail View
2026-08-18 07:33 82824 639226352010431069-3370 S0003591 Fail View
2026-08-18 07:53 82839 639226364049709310-4074 S0003591 Fail View
2026-08-18 07:55 82840 639226365092829288-1841 S0003591 Fail View
2026-08-20 07:25 83852 639228075030247992-5668 S0003591 Fail View

Test 82819

Result
Fail
Date
2026-08-18 07:27
Article
S0003591
ID record
639226348538071123-3129
ID production
Temperature
Humidity
Test duration
3
Error ID
115
Error text
DMM: Měření odporu: F2 (TP10/TP11)

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5603.83357 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1001.38554 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.685795301 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 3.98315294 < 2.5 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (9)
DateValueMinMax
2026-08-18 07:27 1001.386 950 1050
2026-08-18 07:28 1001.419 950 1050
2026-08-18 07:30 1001.357 950 1050
2026-08-18 07:32 1001.342 950 1050
2026-08-18 07:32 1001.31 950 1050
2026-08-18 07:33 1001.301 950 1050
2026-08-18 07:53 1001.385 950 1050
2026-08-18 07:55 1001.377 950 1050
2026-08-20 07:25 1001.514 950 1050