Serial C00000562

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-18 07:10 82807 639226337812886409-6583 S0003591 Fail View
2026-08-18 07:12 82808 639226339129457276-4657 S0003591 Fail View
2026-08-18 07:17 82812 639226341775674570-6075 S0003591 Pass View

Test 82808

Result
Fail
Date
2026-08-18 07:12
Article
S0003591
ID record
639226339129457276-4657
ID production
Temperature
Humidity
Test duration
26
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5595.89896 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 997.823231 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.698655203 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.718511551 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1397595.56 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.20264428 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.28873715 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28068393 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.27923221 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.80138182 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9704249 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0150577 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9589072 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-08-18 07:10 997.87 950 1050
2026-08-18 07:12 997.823 950 1050
2026-08-18 07:17 997.846 950 1050