Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000562

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-18 07:10 82807 639226337812886409-6583 S0003591 Fail View
2026-08-18 07:12 82808 639226339129457276-4657 S0003591 Fail View
2026-08-18 07:17 82812 639226341775674570-6075 S0003591 Pass View

Test 82807

Result
Fail
Date
2026-08-18 07:10
Article
S0003591
ID record
639226337812886409-6583
ID production
Temperature
Humidity
Test duration
24
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5596.14563 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 997.870223 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.685093148 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.695106443 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1228693.88 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.1513449 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29299891 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.2861691 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.29146348 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.80197126 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9925627 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0236417 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9649179 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-08-18 07:10 997.87 950 1050
2026-08-18 07:12 997.823 950 1050
2026-08-18 07:17 997.846 950 1050