Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C00000650

Tests4
Approved1
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-08-17 12:43 82760 639225674070489521-4990 S0003591 Fail View
2026-08-17 12:44 82761 639225674740667967-3684 S0003591 Fail View
2026-08-17 12:46 82762 639225675571022932-8150 S0003591 Fail View
2026-08-18 06:16 82770 639226305563892028-9681 S0003591 Pass View

Test 82761

Result
Fail
Date
2026-08-17 12:44
Article
S0003591
ID record
639225674740667967-3684
ID production
Temperature
Humidity
Test duration
14
Error ID
208
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5610.62538 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 996.224936 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.705966961 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.919820567 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1398879.21 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.18944406 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.2927864 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.2846192 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.28283328 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79853875 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9888383 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.00883131 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 12.0112637 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-08-17 12:43 996.252 950 1050
2026-08-17 12:44 996.225 950 1050
2026-08-17 12:46 996.23 950 1050
2026-08-18 06:16 996.25 950 1050