Serial lookup
Search a serial number to see its full test history.
Serial C01000914
Tests3
Approved0
Failures3
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-08-13 09:22 | 82031 | 639222097164227326-4462 | S0003590 | Fail | View |
| 2026-08-13 10:22 | 82101 | 639222133236675350-1893 | S0003590 | Fail | View |
| 2026-08-13 12:07 | 82192 | 639222196202450284-8552 | S0003590 | Fail | View |
Test 82192
- Result
- Fail
- Date
- 2026-08-13 12:07
- Article
- S0003590
- ID record
- 639222196202450284-8552
- ID production
- Temperature
- Humidity
- Test duration
- 38
- Error ID
- 194
- Error text
- TestSW: test oscilátoru ON
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5636.54422 | 5320 | 5880 | Pass |
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 998.985395 | 950 | 1050 | Pass |
| 1.2.1 | Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) | 0.613695 | 0 | 10 | Pass |
| 1.2.2 | Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) | 0.747617 | 0 | 10 | Pass |
| 1.2.3 | Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) | 420592.027429 | 400000 | 460000 | Pass |
| 2.2.1 | DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) | 3.28296377 | 3.1 | 3.4 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) | 3.27695683 | 3.1 | 3.4 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 VDDA (TP2/TP24) | 3.28275493 | 3.1 | 3.4 | Pass |
| 2.2.4 | DMM: Měření napětí: +1V8 Audio (TP2/TP26) | 1.79753138 | 1.74 | 1.86 | Pass |
| 2.3.1 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.9415429 | 11.7 | 12.3 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (3)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-08-13 09:22 | 5636.794 | 5320 | 5880 |
| 2026-08-13 10:22 | 5636.696 | 5320 | 5880 |
| 2026-08-13 12:07 | 5636.544 | 5320 | 5880 |