Serial lookup
Search a serial number to see its full test history.
Serial C01000614
Tests3
Approved1
Failures2
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-08-13 07:44 | 81948 | 639222038528611780-3266 | S0003590 | Fail | View |
| 2026-08-13 07:46 | 81949 | 639222039470041019-4337 | S0003590 | Fail | View |
| 2026-08-13 07:47 | 81950 | 639222040159271900-9714 | S0003590 | Pass | View |
Test 81949
- Result
- Fail
- Date
- 2026-08-13 07:46
- Article
- S0003590
- ID record
- 639222039470041019-4337
- ID production
- Temperature
- Humidity
- Test duration
- 38
- Error ID
- 194
- Error text
- TestSW: test oscilátoru ON
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5614.30682 | 5320 | 5880 | Pass |
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 999.082469 | 950 | 1050 | Pass |
| 1.2.1 | Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) | 0.587539 | 0 | 10 | Pass |
| 1.2.2 | Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) | 0.989859 | 0 | 10 | Pass |
| 1.2.3 | Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) | 420654.210714 | 400000 | 460000 | Pass |
| 2.2.1 | DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) | 3.28472548 | 3.1 | 3.4 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) | 3.2787136 | 3.1 | 3.4 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 VDDA (TP2/TP24) | 3.28424408 | 3.1 | 3.4 | Pass |
| 2.2.4 | DMM: Měření napětí: +1V8 Audio (TP2/TP26) | 1.80143233 | 1.74 | 1.86 | Pass |
| 2.3.1 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.9929624 | 11.7 | 12.3 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (3)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-08-13 07:44 | 999.11 | 950 | 1050 |
| 2026-08-13 07:46 | 999.082 | 950 | 1050 |
| 2026-08-13 07:47 | 999.095 | 950 | 1050 |