Serial 001791472

Tests12
Approved1
Failures11

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-19 07:33 391 638623207428728363-5719 S0001055 Fail View
2024-09-19 07:35 392 638623209106098495-4337 S0001055 Fail View
2024-09-19 08:10 393 638623229949531348-4458 S0001055 Fail View
2024-12-05 14:54 5399 638690036072711655-9636 S0001055 Fail View
2024-12-05 15:21 5400 638690052492105046-5215 S0001055 Fail View
2025-09-05 11:27 25761 638926612215708654-3950 S0001055 Fail View
2025-11-06 17:29 40585 638980433396166126-5959 S0001055 Fail View
2026-07-09 14:48 77745 639192052730225671-9974 S0001055 Fail View
2026-07-09 14:49 77746 639192053380116589-3555 S0001055 Fail View
2026-08-11 04:41 81270 639220200196191802-4191 S0001055 Fail View
2026-08-11 04:51 81271 639220206265241579-4710 S0001055 Fail View
2026-09-23 05:29 86096 639257381296897102-3479 S0001055 Pass View

Test 81271

Result
Fail
Date
2026-08-11 04:51
Article
S0001055
ID record
639220206265241579-4710
ID production
49267
Temperature
25.31
Humidity
44.96
Test duration
62
Error ID
447
Error text
DMM: měření RMS(TP49/TP67)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.75264796 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1000.44012 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00451 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0003490755 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00451 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02414192 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9652098 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9971956 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8871284 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.00411726 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.29612546 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.29613973 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.68425916 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.6804799 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.68101932 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.514721521 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7948931 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00451 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.01177106 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.100069 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5334358 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3140681 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.60765626 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00451 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02530298 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3842 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2027 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2026 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2026 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2024 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.29233808 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00346119581 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.29364552 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00344925292 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.29203073 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00359596202 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.29225414 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.0034745194 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 56 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1889 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.1875 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0067267 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1833 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1871 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0072785 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1833 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1857 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0110826 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.000475062246 < 0.5 Pass
20.0.5 Analysis: VA VA[2278] 2210 2340 Pass
20.0.6 Analysis: VB VB[2275] 2210 2340 Pass
20.0.7 Analysis: VC VC[2278] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00451 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989402 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2451 2443[VA] 2543[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2105 2010[VB] 2110[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2279 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.0379479 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989364 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2105 2013[VA] 2113[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2442 2440[VB] 2540[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2279 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989364 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2451 2443[VA] 2543[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2278 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2112 2013[VC] 2113[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989457 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2104 2013[VA] 2113[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2273 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2443 2443[VC] 2543[VC] Pass
20.5.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989331 4.7 5.3 Pass
20.5.2 TestSW: [ADC_PA0] sense A 2278 2210 2340 Pass
20.5.3 TestSW: [ADC_PA1] sense B 2446 2440[VB] 2540[VB] Pass
20.5.4 TestSW: [ADC_PA2] sense C 2112 2013[VC] 2113[VC] Pass
20.6.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989563 4.7 5.3 Pass
20.6.2 TestSW: [ADC_PA0] sense A 2278 2210 2340 Pass
20.6.3 TestSW: [ADC_PA1] sense B 2104 2010[VB] 2110[VB] Pass
20.6.4 TestSW: [ADC_PA2] sense C 2444 2443[VC] 2543[VC] Pass
23.1 DMM: měření RMS(TP49/TP67) 0.0822689847 0.1 1.6 Fail
23.1 DMM: měření RMS(TP49/TP67) 0.0819006215 0.1 1.6 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (5)
DateValueMinMax
2026-07-09 14:48 1.022 10
2026-07-09 14:49 0.976 10
2026-08-11 04:41 0.771 10
2026-08-11 04:51 0.753 10
2026-09-23 05:29 0.811 10