Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 002490180

Tests7
Approved3
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-07-31 04:17 81140 639210682568556596-4949 S0004684 Fail View
2026-07-31 04:50 81146 639210702077829734-8811 S0004684 Fail View
2026-07-31 04:52 81147 639210703225847921-7541 S0004684 Fail View
2026-09-02 04:54 84827 639239215937049332-9773 S0004684 Pass View
2026-09-02 05:35 84836 639239240450463861-1207 S0004684 Pass View
2026-09-02 05:36 84837 639239241326794884-9099 S0004684 Pass View
2026-09-02 05:37 84838 639239242252076795-4930 S0004684 Fail View

Test 81147

Result
Fail
Date
2026-07-31 04:52
Article
S0004684
ID record
639210703225847921-7541
ID production
57283
Temperature
25.57
Humidity
46.52
Test duration
12
Error ID
144
Error text
DMM: Měření napětí: U_BAT naprázdno (TP1/TP5)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Měření napětí: +12V (TP1/TP72) 12.0518506 11.8 12.3 Pass
1.2 DMM: Měření napětí: +3,3V (TP1/TP6) 3.30936355 3.2 3.4 Pass
1.3 DMM: Měření napětí: U_MAT (TP1/TP66) 12.0517103 11.7 12.3 Pass
1.4 DMM: Měření napětí: U_MAT_BAT (TP1/TP63) 3.11287639E-05 < 0.1 Pass
2.6.1 DMM: Měření napětí: PRQ_IN (TP1/TP51) 1.60547527 1.5 1.9 Pass
2.6.2 DMM: Měření napětí: PRQ_IN (TP1/TP67) 12.0522175 11.8 12.3 Pass
2.6.3 DMM: Měření napětí: PRQ_IN (TP1/TP52) 1.58166543 1.5 1.7 Pass
3.1 NZ3: Měření napětí: Zkrat? 30.00641 > 29.9 Pass
3.2 DMM: Měření napětí: U_BAT naprázdno (TP1/TP5) 29.7133206 27 29 Fail

Measurements over time

No plottable values for this measurement.

Readings (4)
DateValueMinMax
2026-09-02 04:54
2026-09-02 05:35
2026-09-02 05:36
2026-09-02 05:37