Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 002421594

Tests3
Approved0
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-07-17 13:44 79730 639198926646613556-9030 S0001055 Fail View
2026-07-17 13:45 79731 639198927190874888-3905 S0001055 Fail View
2026-07-17 15:34 79801 639198992354507553-3988 S0001055 Fail View

Test 79801

Result
Fail
Date
2026-07-17 15:34
Article
S0001055
ID record
639198992354507553-3988
ID production
52269
Temperature
25.45
Humidity
45.45
Test duration
17
Error ID
142
Error text
DMM: Měření napětí: (TP49/TP46)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.735689328 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1002.14836 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0009472628 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02455445 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9738009 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9965854 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.7741558 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98797391 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30508399 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.30507857 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66891951 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.66422688 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.66662063 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.53882647 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 4.64066525 > 11.5 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-17 13:44 0.783 10
2026-07-17 13:45 0.775 10
2026-07-17 15:34 0.736 10