Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 002342287

Tests3
Approved0
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-07-14 12:07 78472 639196276060248449-1430 S0004022 Fail View
2026-07-14 12:54 78506 639196304323103089-8084 S0004022 Fail View
2026-07-14 14:33 78587 639196364022912607-5987 S0004022 Fail View

Test 78472

Result
Fail
Date
2026-07-14 12:07
Article
S0004022
ID record
639196276060248449-1430
ID production
56129
Temperature
26.91
Humidity
54.79
Test duration
24
Error ID
179
Error text
DMM: Měření napětí: LED W (TP44/TP3)

Measurement lines

StepNameValueMinMaxResult
1.0.1 DMM: Měření odporu: R1 (TP4/TP5) 0.473068551 < 5 Pass
1.0.2 DMM: Měření odporu: R2 (TP6/TP5) 4708.12277 4400 5000 Pass
1.0.3 DMM: Měření odporu: FBA4-PTC1-R53-PTC2-FBA4 (TP27/TP28) 1075.02231 1000 1200 Pass
1.0.4 DMM: Měření proudu: sloupec A (TP16/TP3) 0.000996124976 0.0009 0.0011 Pass
1.1.1 DMM: Měření napětí: +3V3 (TP8/TP3) 3.31337505 3.2 3.4 Pass
1.1.2 DMM: Měření napětí: +VDDA (TP9/TP3) 3.31282542 3.2 3.4 Pass
1.1.3 DMM: Měření napětí: BCK_RO_28V (TP25/TP3) 26.1975478 23.6 28.5 Pass
3.1.1 DMM: Měření proudu: BCK (LED) RO (TP34/TP3) 0.0170061225 0.016 0.02 Pass
3.1.2 DMM: Měření proudu: BCK (LED) RO (TP34/TP3) 2.03821717E-10 < 0.001 Pass
3.2.1 DMM: Měření proudu: LED G (TP35/TP3) 0.0198779053 0.016 0.02 Pass
3.2.2 DMM: Měření napětí: LED G (TP43/TP3) 2.99805021 2.955 3.1 Pass
3.2.3 DMM: Měření proudu: LED G (TP35/TP3) 8.39968415E-10 < 0.001 Pass
3.3.1 DMM: Měření proudu: LED W (TP36/TP3) 0.0197609438 0.016 0.022 Pass
3.3.2 DMM: Měření napětí: LED W (TP44/TP3) 2.92842131 2.935 2.99 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-14 12:07 0.473 5
2026-07-14 12:54 0.472 5
2026-07-14 14:33 0.461 5