Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C01000329

Tests5
Approved3
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-02-19 10:31 53483 639070938163754749-2561 S0003590 Fail View
2026-02-19 10:32 53484 639070938853279361-9694 S0003590 Pass View
2026-02-20 07:33 53661 639071695645139366-9010 S0003590 Pass View
2026-07-14 11:12 78426 639196243243381106-9063 S0003590 Fail View
2026-07-14 11:14 78428 639196244090553719-5911 S0003590 Pass View

Test 78426

Result
Fail
Date
2026-07-14 11:12
Article
S0003590
ID record
639196243243381106-9063
ID production
Temperature
Humidity
Test duration
31
Error ID
186
Error text
Vyhodnocení programu: [testSW]

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5596.08746 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 1000.82226 950 1050 Pass
1.2.1 Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) 0.56725 0 10 Pass
1.2.2 Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) 0.672294 0 10 Pass
1.2.3 Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) 420643.091857 400000 460000 Pass
2.2.1 DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) 3.2994166 3.1 3.4 Pass
2.2.2 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) 3.29342891 3.1 3.4 Pass
2.2.3 DMM: Měření napětí: +3V3 VDDA (TP2/TP24) 3.29892716 3.1 3.4 Pass
2.2.4 DMM: Měření napětí: +1V8 Audio (TP2/TP26) 1.79945923 1.74 1.86 Pass
2.3.1 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9766293 11.7 12.3 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-07-14 11:12 1000.822 950 1050
2026-07-14 11:14 1000.806 950 1050