Serial C01000177
Tests11
Approved2
Failures9
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-12-11 13:52 | 23282 | 639010579004945643-8600 | S0003590 | Pass | View |
| 2026-07-13 08:21 | 77932 | 639195276228410811-7912 | S0003590 | Fail | View |
| 2026-07-13 08:22 | 77933 | 639195277012790783-3182 | S0003590 | Fail | View |
| 2026-07-13 08:27 | 77936 | 639195280058130407-5214 | S0003590 | Fail | View |
| 2026-07-13 08:28 | 77937 | 639195280708202875-9549 | S0003590 | Fail | View |
| 2026-07-13 10:57 | 78013 | 639195370154653168-8512 | S0003590 | Fail | View |
| 2026-07-14 05:32 | 78246 | 639196039225320987-1933 | S0003590 | Fail | View |
| 2026-07-14 05:33 | 78247 | 639196039936970459-8970 | S0003590 | Fail | View |
| 2026-07-14 07:53 | 78333 | 639196123760005786-9148 | S0003590 | Fail | View |
| 2026-07-14 07:55 | 78334 | 639196125042804923-6972 | S0003590 | Fail | View |
| 2026-07-14 10:47 | 78420 | 639196228064457671-1505 | S0003590 | Pass | View |
Test 78247
- Result
- Fail
- Date
- 2026-07-14 05:33
- Article
- S0003590
- ID record
- 639196039936970459-8970
- ID production
- Temperature
- Humidity
- Test duration
- 45
- Error ID
- 265
- Error text
- DMM: Měření odporu: (TP39/TP40)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 1001.4253 | 950 | 1050 | Pass |
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5604.64817 | 5320 | 5880 | Pass |
| 1.2.1 | Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) | 0.580476 | 0 | 10 | Pass |
| 1.2.2 | Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) | 0.695244 | 0 | 10 | Pass |
| 1.2.3 | Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) | 420796.506714 | 400000 | 460000 | Pass |
| 2.2.1 | DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) | 3.28178765 | 3.1 | 3.4 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) | 3.27569352 | 3.1 | 3.4 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 VDDA (TP2/TP24) | 3.28131345 | 3.1 | 3.4 | Pass |
| 2.2.4 | DMM: Měření napětí: +1V8 Audio (TP2/TP26) | 1.80053414 | 1.74 | 1.86 | Pass |
| 2.3.1 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.9245083 | 11.7 | 12.3 | Pass |
| 3.2.1 | DMM: Měření frekvence: 1kHz (TP2/TP16) | 1000.01079 | 999.8 | 1000.2 | Pass |
| 3.3.1 | NZ3.2: Měření proudu: Kontrola odběru | 0.005016124 | < | 0.02 | Pass |
| 3.3.2 | NZ3.2: Měření proudu: Kontrola odběru | 0.005025043 | < | 0.2 | Pass |
| 3.4.1 | DMM: Měření odporu: (TP33/TP32) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.2 | DMM: Měření odporu: (TP33/TP32) | 0.576547423 | < | 7 | Pass |
| 3.4.3 | DMM: Měření odporu: (TP35/TP34) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.4 | DMM: Měření odporu: (TP35/TP34) | 0.587700763 | < | 7 | Pass |
| 3.4.5 | DMM: Měření odporu: (TP37/TP36) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.6 | DMM: Měření odporu: (TP37/TP36) | 0.627005616 | < | 7 | Pass |
| 3.4.7 | DMM: Měření odporu: (TP39/TP40) | 9.9E+37 | > | 10000000 | Pass |
| 3.4.8 | DMM: Měření odporu: (TP39/TP40) | 9.9E+37 | 90 | 150 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (10)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-13 08:21 | 1001.446 | 950 | 1050 |
| 2026-07-13 08:22 | 1001.4 | 950 | 1050 |
| 2026-07-13 08:27 | 1001.432 | 950 | 1050 |
| 2026-07-13 08:28 | 1001.441 | 950 | 1050 |
| 2026-07-13 10:57 | 1001.442 | 950 | 1050 |
| 2026-07-14 05:32 | 1001.453 | 950 | 1050 |
| 2026-07-14 05:33 | 1001.425 | 950 | 1050 |
| 2026-07-14 07:53 | 1001.467 | 950 | 1050 |
| 2026-07-14 07:55 | 1001.479 | 950 | 1050 |
| 2026-07-14 10:47 | 1001.511 | 950 | 1050 |