Serial lookup
Search a serial number to see its full test history.
Serial C01000082
Tests3
Approved2
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-12-11 09:27 | 23086 | 639010420217204851-2449 | S0003590 | Pass | View |
| 2026-07-14 04:59 | 78228 | 639196019088230083-4262 | S0003590 | Fail | View |
| 2026-07-14 05:00 | 78229 | 639196019800726041-6029 | S0003590 | Pass | View |
Test 78228
- Result
- Fail
- Date
- 2026-07-14 04:59
- Article
- S0003590
- ID record
- 639196019088230083-4262
- ID production
- Temperature
- Humidity
- Test duration
- 31
- Error ID
- 186
- Error text
- Vyhodnocení programu: [testSW]
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5604.30598 | 5320 | 5880 | Pass |
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 997.813828 | 950 | 1050 | Pass |
| 1.2.1 | Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) | 3.319324 | 0 | 10 | Pass |
| 1.2.2 | Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) | 0.995421 | 0 | 10 | Pass |
| 1.2.3 | Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) | 420692.174 | 400000 | 460000 | Pass |
| 2.2.1 | DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) | 3.29364293 | 3.1 | 3.4 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP15) | 3.28741014 | 3.1 | 3.4 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 VDDA (TP2/TP24) | 3.29331882 | 3.1 | 3.4 | Pass |
| 2.2.4 | DMM: Měření napětí: +1V8 Audio (TP2/TP26) | 1.79961122 | 1.74 | 1.86 | Pass |
| 2.3.1 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 12.024087 | 11.7 | 12.3 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-14 04:59 | 997.814 | 950 | 1050 |
| 2026-07-14 05:00 | 997.793 | 950 | 1050 |