Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 002421913

Tests2
Approved1
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-07-13 14:34 78177 639195500475574522-6776 S0001055 Fail View
2026-07-13 14:53 78193 639195511727009099-8040 S0001055 Pass View

Test 78177

Result
Fail
Date
2026-07-13 14:34
Article
S0001055
ID record
639195500475574522-6776
ID production
52269
Temperature
26.71
Humidity
50.67
Test duration
10
Error ID
109
Error text
DMM: Měření napětí: +BATT (TP49/TP34)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.957559121 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1002.40855 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.002532667 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02532653 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9750007 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 2.96657581 27.9 28.1 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-07-13 14:34 0.958 10
2026-07-13 14:53 0.959 10