Serial lookup
Search a serial number to see its full test history.
Serial 002421913
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-07-13 14:34 | 78177 | 639195500475574522-6776 | S0001055 | Fail | View |
| 2026-07-13 14:53 | 78193 | 639195511727009099-8040 | S0001055 | Pass | View |
Test 78177
- Result
- Fail
- Date
- 2026-07-13 14:34
- Article
- S0001055
- ID record
- 639195500475574522-6776
- ID production
- 52269
- Temperature
- 26.71
- Humidity
- 50.67
- Test duration
- 10
- Error ID
- 109
- Error text
- DMM: Měření napětí: +BATT (TP49/TP34)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 0.957559121 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 1002.40855 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.002532667 | < | 0.005 | Pass |
| 3.3 | R11.12: Zapnutí (TP42/TP43) | Pass | |||
| 3.4 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 3.5 | NZ3.1: Měření proudu: Kontrola odběru | 0.02532653 | < | 0.04 | Pass |
| 4.1 | DMM: Měření napětí: +BATT (TP49/TP44) | 27.9750007 | 27.9 | 28.1 | Pass |
| 4.2 | DMM: Měření napětí: +BATT (TP49/TP34) | 2.96657581 | 27.9 | 28.1 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-13 14:34 | 0.958 | — | 10 |
| 2026-07-13 14:53 | 0.959 | — | 10 |