Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial C01000081

Tests6
Approved2
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-12-11 09:26 23085 639010419393454649-9516 S0003590 Pass View
2026-07-13 11:29 78033 639195389513363916-9458 S0003590 Fail View
2026-07-13 11:30 78034 639195389877936859-9188 S0003590 Fail View
2026-07-13 11:31 78035 639195390438713900-5289 S0003590 Fail View
2026-07-13 11:32 78036 639195391084127410-5170 S0003590 Fail View
2026-07-14 05:29 78243 639196036699188723-8187 S0003590 Pass View

Test 78035

Result
Fail
Date
2026-07-13 11:31
Article
S0003590
ID record
639195390438713900-5289
ID production
Temperature
Humidity
Test duration
23
Error ID
150
Error text
DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13)

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5608.41697 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 999.154353 950 1050 Pass
1.2.1 Kontrola vypočítaného průměru z odporů: F1 (TP9/TP8) 0.57475 0 10 Pass
1.2.2 Kontrola vypočítaného průměru z odporů: F2 (TP10/TP11) 0.779811 0 10 Pass
1.2.3 Kontrola vypočítaného průměru z odporů: R3+R4 (TP10/TP8) 420693.457143 400000 460000 Pass
2.2.1 DMM: Měření napětí: +3V3 LDO OUTPUT (TP2/TP13) 0.0113068328 3.1 3.4 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (5)
DateValueMinMax
2026-07-13 11:29 999.208 950 1050
2026-07-13 11:30 999.182 950 1050
2026-07-13 11:31 999.154 950 1050
2026-07-13 11:32 999.149 950 1050
2026-07-14 05:29 999.216 950 1050