Serial lookup
Search a serial number to see its full test history.
Serial 001676219
Tests4
Approved0
Failures4
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-09-05 10:18 | 25789 | 638926570967140404-1417 | S0001055 | Fail | View |
| 2025-11-06 17:11 | 40602 | 638980422298211677-8770 | S0001055 | Fail | View |
| 2026-07-09 16:19 | 77802 | 639192107643203302-6804 | S0001055 | Fail | View |
| 2026-07-09 16:20 | 77803 | 639192108086312523-4199 | S0001055 | Fail | View |
Test 77802
- Result
- Fail
- Date
- 2026-07-09 16:19
- Article
- S0001055
- ID record
- 639192107643203302-6804
- ID production
- 49348
- Temperature
- 26.16
- Humidity
- 34.8
- Test duration
- 34
- Error ID
- 249
- Error text
- TestSW: [BTN_ULCK][ADC_PA7]?
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 1.11000617 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 1002.09837 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.001380449 | < | 0.005 | Pass |
| 3.3 | R11.12: Zapnutí (TP42/TP43) | Pass | |||
| 3.4 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 3.5 | NZ3.1: Měření proudu: Kontrola odběru | 0.02444837 | < | 0.04 | Pass |
| 4.1 | DMM: Měření napětí: +BATT (TP49/TP44) | 27.9643461 | 27.9 | 28.1 | Pass |
| 4.2 | DMM: Měření napětí: +BATT (TP49/TP34) | 27.9965137 | 27.9 | 28.1 | Pass |
| 4.3 | DMM: Měření napětí: +12V (TP49/TP46) | 11.8594766 | 11 | 12.2 | Pass |
| 4.4 | DMM: Měření napětí: +5V (TP49/TP7) | 4.9745432 | 4.9 | 5.1 | Pass |
| 4.5 | DMM: Měření napětí: +3V3 (TP49/TP16) | 3.31001344 | 3.2 | 3.4 | Pass |
| 4.6 | DMM: Měření napětí: VDDA +3V3 (TP49/TP2) | 3.31001734 | 3.2 | 3.4 | Pass |
| 4.7 | DMM: Měření napětí: (TP49/TP8) | 4.65769366 | 4.57 | 4.77 | Pass |
| 4.8 | DMM: Měření napětí: (TP49/TP9) | 4.65482629 | 4.57 | 4.77 | Pass |
| 4.9 | DMM: Měření napětí: (TP49/TP10) | 4.65377772 | 4.57 | 4.77 | Pass |
| 5.1 | DMM: Měření napětí: (TP49/TP46) | 0.560448784 | < | 1 | Pass |
| 5.2 | DMM: Měření napětí: (TP49/TP46) | 11.7750222 | > | 11.5 | Pass |
| 6.1 | R9.12: Vypnutí (TP49/TP28) | Pass | |||
| 7.1 | NZ3: Měření napětí: Zkrat? | 28.00851 | > | 27.9 | Pass |
| 7.2 | NZ3: Měření proudu: Kontrola odběru | 0.02543261 | < | 0.06 | Pass |
| 7.3 | R0.6: Zapnutí Ext. Programátoru | Pass | |||
| 8.1 | TestSw: Ověření komunikace | [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: | Pass | ||
| 9.1 | TestSW: [CHG_SIG (PC14)] = log1? | 16384 | 16384 | 16384 | Pass |
| 9.2 | EL1.1: Ověření proudu na zátěži -> Current? | 2.068788 | 1.6 | 2.8 | Pass |
| 9.3 | DMM: Měření napětí: Vstup U14 (TP39/TP32) | 29.5590148 | 29 | 30.1 | Pass |
| 9.4 | DMM: Měření napětí: Vstup U14 (TP39/TP33) | 11.2957438 | 10.8 | 11.5 | Pass |
| 9.5 | DMM: Měření napětí: Vstup U14 (TP39/TP40) | 1.59820051 | 1.5 | 1.8 | Pass |
| 10.1 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 10.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.02522337 | < | 0.06 | Pass |
| 10.3 | TestSW: [ADC_PA03] | 3834 | 3667 | 3937 | Pass |
| 12.1 | TestSW: [PA15] - napájení sense ABC | Pass | |||
| 12.2 | TestSW: [HALL_A (PB4)] = log0? | 0 | 0 | 0 | Pass |
| 12.3 | TestSW: [HALL_A (PB4)] = log1? | 16 | 16 | 16 | Pass |
| 12.4 | TestSW: [HALL_B (PB5)] = log0? | 0 | 0 | 0 | Pass |
| 12.5 | TestSW: [HALL_B (PB5)] = log1? | 32 | 32 | 32 | Pass |
| 12.6 | TestSW: [HALL_C (PB0)] = log0? | 0 | 0 | 0 | Pass |
| 12.7 | TestSW: [HALL_C (PB0)] = log1? | 1 | 1 | 1 | Pass |
| 13.1 | TestSW: [CON_ID (PC13)] = log1? | 8192 | 8192 | 8192 | Pass |
| 13.2 | TestSW: [CON_ID (PC13)] = log0? | 0 | 0 | 0 | Pass |
| 13.3 | TestSW: [BTN_DRV][PA11] na log1 | Pass | |||
| 13.4 | TestSW: [BTN_FWD][ADC_PB1]? | 4084 | 4000 | 4096 | Pass |
| 13.5 | TestSW: [BTN_FWD][ADC_PB1]? | 2015 | 1900 | 2100 | Pass |
| 13.6 | TestSW: [BTN_REV][ADC_PA4]? | 4085 | 4000 | 4096 | Pass |
| 13.7 | TestSW: [BTN_REV][ADC_PA4]? | 2037 | 1900 | 2100 | Pass |
| 13.8 | TestSW: [BTN_ULCK][ADC_PA7]? | 4089 | 4000 | 4096 | Pass |
| 13.9 | TestSW: [BTN_ULCK][ADC_PA7]? | 4089 | 1900 | 2100 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-09 16:19 | 1.11 | — | 10 |
| 2026-07-09 16:20 | 1.007 | — | 10 |