Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001676245

Tests4
Approved0
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-09-05 09:50 25794 638926554131911452-8511 S0001055 Fail View
2025-11-06 17:10 40603 638980421972479432-3624 S0001055 Fail View
2026-07-09 16:18 77800 639192107058759252-2390 S0001055 Fail View
2026-07-09 16:18 77801 639192107231072342-2393 S0001055 Fail View

Test 77801

Result
Fail
Date
2026-07-09 16:18
Article
S0001055
ID record
639192107231072342-2393
ID production
49348
Temperature
26.16
Humidity
34.8
Test duration
9
Error ID
102
Error text
NZ3.1: Měření proudu: Kontrola odběru

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 1.23130845 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 997.229889 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.00051997 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.06904552 < 0.04 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-07-09 16:18 2.396 10
2026-07-09 16:18 1.231 10