Serial 001676183

Tests5
Approved0
Failures5

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-09-05 10:50 25783 638926590299318656-6307 S0001055 Fail View
2025-11-06 17:09 40601 638980421119682234-2572 S0001055 Fail View
2026-07-09 15:58 77788 639192094459313365-2542 S0001055 Fail View
2026-07-09 16:04 77789 639192098208636849-7762 S0001055 Fail View
2026-07-09 16:05 77790 639192098845698841-4002 S0001055 Fail View

Test 77788

Result
Fail
Date
2026-07-09 15:58
Article
S0001055
ID record
639192094459313365-2542
ID production
49348
Temperature
25.48
Humidity
35.78
Test duration
54
Error ID
371
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 1.12067 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1002.22914 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.001421705 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02450436 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9646138 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9960267 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8455389 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98963668 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.32018705 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.32018918 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.67297587 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.66971046 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.66844753 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.562839305 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7554246 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02568604 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 1.989216 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5936142 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.2824743 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.5464161 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02537957 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3813 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2039 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4086 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2040 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2015 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2035 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2034 1900 2100 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.31558037 > 3 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00349116317 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.31684644 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00348338778 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.31545002 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00360122121 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.31556157 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00358478081 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 86 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.2831 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.2812 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0052843 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.2737 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.2775 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0049348 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.2756 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.2793 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0027012 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0.0122077515 < 0.5 Pass
20.0.5 Analysis: VA VA[2256] 2210 2340 Pass
20.0.7 Analysis: VC VC[2257] 2210 2340 Pass
20.0.6 Analysis: VB VB[2252] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989844 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2425 2421[VA] 2521[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2087 1987[VB] 2087[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2257 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03801565 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.98979 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2088 1991[VA] 2091[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2416 2417[VB] 2517[VB] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-07-09 15:58 1.121 10
2026-07-09 16:04 1.021 10
2026-07-09 16:05 1.001 10