Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001791580

Tests13
Approved1
Failures12

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-04 14:18 120 638610490692017824-6076 S0001055 Fail View
2024-09-04 14:44 121 638610506211302571-9122 S0001055 Fail View
2024-09-23 08:54 525 638626712179833309-7388 S0001055 Fail View
2024-12-05 15:02 5425 638690041226339881-7396 S0001055 Fail View
2024-12-05 15:18 5426 638690050503788650-1421 S0001055 Fail View
2025-09-05 11:34 25773 638926615940184172-8600 S0001055 Fail View
2025-11-06 17:26 40595 638980431637054293-8233 S0001055 Fail View
2026-07-09 14:56 77750 639192057461952391-5550 S0001055 Fail View
2026-07-09 15:30 77774 639192077659903818-4534 S0001055 Fail View
2026-07-09 15:31 77775 639192078342481215-9283 S0001055 Fail View
2026-07-09 15:32 77776 639192079224402463-4603 S0001055 Fail View
2026-07-09 15:34 77777 639192079918677658-2895 S0001055 Fail View
2026-08-11 04:53 81272 639220207238377596-2682 S0001055 Pass View

Test 77774

Result
Fail
Date
2026-07-09 15:30
Article
S0001055
ID record
639192077659903818-4534
ID production
49267
Temperature
25.46
Humidity
36.38
Test duration
56
Error ID
424
Error text
TestSW: [ADC_PA2] sense C

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.987014453 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1004.96823 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0004610331 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02432165 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9718428 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9971372 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8502401 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.00377436 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.31007612 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.31008783 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.68458132 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.68083891 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.67990802 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.517787275 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.7611646 > 11.5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0.02552102 < 0.06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2.103189 1.6 2.8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29.5627662 29 30.1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11.3104187 10.8 11.5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1.60969019 1.5 1.8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0.02551805 < 0.06 Pass
10.3 TestSW: [ADC_PA03] 3826 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2025 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2027 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2010 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2027 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2029 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3.30595909 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0.00356916109 < 0.1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3.30723663 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0.00351085067 < 0.1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3.30576993 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0.00368811069 < 0.1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3.3059212 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0.00357118994 < 0.1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 58 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995.1513 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995.1513 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14.0123846 13.3 14.7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995.1475 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995.1517 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14.0091085 13.3 14.7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995.1456 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995.1498 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14.0034637 13.3 14.7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0.00703115478 < 0.5 Pass
20.0.5 Analysis: VA VA[2267] 2210 2340 Pass
20.0.6 Analysis: VB VB[2268] 2210 2340 Pass
20.0.7 Analysis: VC VC[2268] 2210 2340 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989606 4.7 5.3 Pass
20.1.2 TestSW: [ADC_PA0] sense A 2441 2432[VA] 2532[VA] Pass
20.1.3 TestSW: [ADC_PA1] sense B 2098 2003[VB] 2103[VB] Pass
20.1.4 TestSW: [ADC_PA2] sense C 2268 2210 2340 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0.03820425 < 0.06 Pass
20.2.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989627 4.7 5.3 Pass
20.2.2 TestSW: [ADC_PA0] sense A 2092 2002[VA] 2102[VA] Pass
20.2.3 TestSW: [ADC_PA1] sense B 2437 2433[VB] 2533[VB] Pass
20.2.4 TestSW: [ADC_PA2] sense C 2268 2210 2340 Pass
20.3.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989738 4.7 5.3 Pass
20.3.2 TestSW: [ADC_PA0] sense A 2441 2432[VA] 2532[VA] Pass
20.3.3 TestSW: [ADC_PA1] sense B 2271 2210 2340 Pass
20.3.4 TestSW: [ADC_PA2] sense C 2102 2003[VC] 2103[VC] Pass
20.4.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989683 4.7 5.3 Pass
20.4.2 TestSW: [ADC_PA0] sense A 2092 2002[VA] 2102[VA] Pass
20.4.3 TestSW: [ADC_PA1] sense B 2266 2210 2340 Pass
20.4.4 TestSW: [ADC_PA2] sense C 2433 2433[VC] 2533[VC] Pass
20.5.1 EL1.2: Ověření proudu na zátěži -> Current? 4.98964 4.7 5.3 Pass
20.5.2 TestSW: [ADC_PA0] sense A 2267 2210 2340 Pass
20.5.3 TestSW: [ADC_PA1] sense B 2439 2433[VB] 2533[VB] Pass
20.5.4 TestSW: [ADC_PA2] sense C 2103 2003[VC] 2103[VC] Pass
20.6.1 EL1.2: Ověření proudu na zátěži -> Current? 4.989813 4.7 5.3 Pass
20.6.2 TestSW: [ADC_PA0] sense A 2266 2210 2340 Pass
20.6.3 TestSW: [ADC_PA1] sense B 2095 2003[VB] 2103[VB] Pass
20.6.4 TestSW: [ADC_PA2] sense C 2432 2433[VC] 2533[VC] Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (6)
DateValueMinMax
2026-07-09 14:56 1.007 10
2026-07-09 15:30 0.987 10
2026-07-09 15:31 0.967 10
2026-07-09 15:32 0.963 10
2026-07-09 15:34 0.946 10
2026-08-11 04:53 0.777 10