Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001969215

Tests9
Approved1
Failures8

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-10-30 15:23 39990 638974309813151234-1570 S0001055 Fail View
2025-10-30 15:23 39991 638974310039090196-7667 S0001055 Fail View
2026-07-09 12:58 77655 639191987296002745-8769 S0001055 Fail View
2026-07-09 12:59 77656 639191987605634350-5446 S0001055 Fail View
2026-07-09 13:14 77677 639191996958901295-9678 S0001055 Fail View
2026-07-09 13:46 77707 639192015709841380-3099 S0001055 Fail View
2026-07-09 13:46 77708 639192015827497246-6103 S0001055 Fail View
2026-07-09 13:53 77714 639192019969282289-7011 S0001055 Fail View
2026-07-09 14:07 77725 639192027955399687-1275 S0001055 Pass View

Test 77656

Result
Fail
Date
2026-07-09 12:59
Article
S0001055
ID record
639191987605634350-5446
ID production
52267
Temperature
25.74
Humidity
38.91
Test duration
3
Error ID
081
Error text
DMM: Kontrola hodnoty Odporu (TP6/TP4)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 9.9E+37 < 10 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (7)
DateValueMinMax
2026-07-09 12:58 99000000000000000000000000000000000000 10
2026-07-09 12:59 99000000000000000000000000000000000000 10
2026-07-09 13:14 99000000000000000000000000000000000000 10
2026-07-09 13:46 99000000000000000000000000000000000000 10
2026-07-09 13:46 99000000000000000000000000000000000000 10
2026-07-09 13:53 85.201 10
2026-07-09 14:07 1.466 10