Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 002421518

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-06-26 06:23 76191 639180518245779191-9237 S0001055 Fail View
2026-06-26 06:45 76195 639180530946692919-8321 S0001055 Fail View
2026-07-09 12:10 77623 639191957755797707-7908 S0001055 Pass View

Test 76191

Result
Fail
Date
2026-06-26 06:23
Article
S0001055
ID record
639180518245779191-9237
ID production
52269
Temperature
27.57
Humidity
48.22
Test duration
13
Error ID
124
Error text
DMM: Měření napětí: (TP49/TP8)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.84279704 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1001.84575 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.002285131 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02499059 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9743751 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9975096 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8439535 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.97143732 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.31230547 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.31230709 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 1.07594801 4.57 4.77 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-06-26 06:23 0.843 10
2026-06-26 06:45 0.827 10
2026-07-09 12:10 1.692 10