Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 002421930

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-06-26 06:12 76180 639180511647160072-8828 S0001055 Fail View
2026-06-26 06:13 76181 639180511917951115-1923 S0001055 Fail View
2026-06-26 06:56 76203 639180537293952966-5007 S0001055 Pass View

Test 76181

Result
Fail
Date
2026-06-26 06:13
Article
S0001055
ID record
639180511917951115-1923
ID production
52269
Temperature
27.55
Humidity
48.73
Test duration
13
Error ID
124
Error text
DMM: Měření napětí: (TP49/TP8)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.774367575 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 998.595053 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.000617216 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02433344 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9766204 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9980164 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8428344 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 5.00499417 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30838798 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.3084019 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 0.112666708 4.57 4.77 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-06-26 06:12 0.78 10
2026-06-26 06:13 0.774 10
2026-06-26 06:56 0.783 10