Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 002421661

Tests2
Approved1
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-06-26 05:51 76163 639180498878721348-3178 S0001055 Fail View
2026-06-26 05:57 76167 639180501858080758-6357 S0001055 Pass View

Test 76163

Result
Fail
Date
2026-06-26 05:51
Article
S0001055
ID record
639180498878721348-3178
ID production
52269
Temperature
27.44
Humidity
49.47
Test duration
3
Error ID
084
Error text
DMM: Kontrola hodnoty Odporu (TP6/TP5)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.771663012 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 9.9E+37 800 1200 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-06-26 05:51 0.772 10
2026-06-26 05:57 0.766 10