Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 002421665

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-06-26 04:38 76105 639180455012101562-8669 S0001055 Fail View
2026-06-26 04:38 76106 639180455212587281-9211 S0001055 Fail View
2026-06-26 04:42 76109 639180456821977325-5277 S0001055 Pass View

Test 76106

Result
Fail
Date
2026-06-26 04:38
Article
S0001055
ID record
639180455212587281-9211
ID production
52269
Temperature
27.29
Humidity
48.81
Test duration
10
Error ID
106
Error text
DMM: Měření napětí: +BATT (TP49/TP44)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.763151763 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1003.98913 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.0009325286 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02448078 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 24.5675877 27.9 28.1 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-06-26 04:38 0.764 10
2026-06-26 04:38 0.763 10
2026-06-26 04:42 0.764 10