Serial lookup
Search a serial number to see its full test history.
Serial 002421694
Tests4
Approved1
Failures3
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-06-26 04:37 | 76103 | 639180454568954772-2275 | S0001055 | Fail | View |
| 2026-06-26 04:38 | 76104 | 639180454770229471-9559 | S0001055 | Fail | View |
| 2026-07-09 12:14 | 77624 | 639191960663945943-8564 | S0001055 | Fail | View |
| 2026-07-09 12:17 | 77625 | 639191961599921447-5965 | S0001055 | Pass | View |
Test 76104
- Result
- Fail
- Date
- 2026-06-26 04:38
- Article
- S0001055
- ID record
- 639180454770229471-9559
- ID production
- 52269
- Temperature
- 27.29
- Humidity
- 48.81
- Test duration
- 10
- Error ID
- 106
- Error text
- DMM: Měření napětí: +BATT (TP49/TP44)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 0.763413779 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 1007.06839 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.0009001133 | < | 0.005 | Pass |
| 3.3 | R11.12: Zapnutí (TP42/TP43) | Pass | |||
| 3.4 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 3.5 | NZ3.1: Měření proudu: Kontrola odběru | 0.02467527 | < | 0.04 | Pass |
| 4.1 | DMM: Měření napětí: +BATT (TP49/TP44) | 24.5593003 | 27.9 | 28.1 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (4)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-06-26 04:37 | 0.759 | — | 10 |
| 2026-06-26 04:38 | 0.763 | — | 10 |
| 2026-07-09 12:14 | 1.079 | — | 10 |
| 2026-07-09 12:17 | 1.072 | — | 10 |