Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 002421694

Tests4
Approved1
Failures3

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-06-26 04:37 76103 639180454568954772-2275 S0001055 Fail View
2026-06-26 04:38 76104 639180454770229471-9559 S0001055 Fail View
2026-07-09 12:14 77624 639191960663945943-8564 S0001055 Fail View
2026-07-09 12:17 77625 639191961599921447-5965 S0001055 Pass View

Test 76103

Result
Fail
Date
2026-06-26 04:37
Article
S0001055
ID record
639180454568954772-2275
ID production
52269
Temperature
27.29
Humidity
48.81
Test duration
10
Error ID
106
Error text
DMM: Měření napětí: +BATT (TP49/TP44)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.759008218 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1007.07445 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00451 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.002948172 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.025633 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 24.5557426 27.9 28.1 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (4)
DateValueMinMax
2026-06-26 04:37 0.759 10
2026-06-26 04:38 0.763 10
2026-07-09 12:14 1.079 10
2026-07-09 12:17 1.072 10