Serial lookup
Search a serial number to see its full test history.
Serial 002421675
Tests2
Approved1
Failures1
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-06-26 04:25 | 76093 | 639180447064519731-7232 | S0001055 | Fail | View |
| 2026-06-26 04:26 | 76094 | 639180447379986131-6795 | S0001055 | Pass | View |
Test 76093
- Result
- Fail
- Date
- 2026-06-26 04:25
- Article
- S0001055
- ID record
- 639180447064519731-7232
- ID production
- 52269
- Temperature
- 27.39
- Humidity
- 48.3
- Test duration
- 6
- Error ID
- 095
- Error text
- NZ3.1: Měření proudu: Kontrola odběru
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 0.782572741 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 1001.03707 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.005429417 | < | 0.005 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-06-26 04:25 | 0.783 | — | 10 |
| 2026-06-26 04:26 | 0.769 | — | 10 |