Serial 002421685

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-06-26 04:24 76092 639180446662030408-1663 S0001055 Fail View
2026-06-26 04:27 76095 639180448239958638-2988 S0001055 Fail View
2026-07-09 12:00 77617 639191951571691779-8368 S0001055 Pass View

Test 76092

Result
Fail
Date
2026-06-26 04:24
Article
S0001055
ID record
639180446662030408-1663
ID production
52269
Temperature
27.39
Humidity
48.3
Test duration
17
Error ID
142
Error text
DMM: Měření napětí: (TP49/TP46)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.762393694 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999.853832 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.002420686 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02514382 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9677447 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9915758 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.8751721 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98181368 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.31057556 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.31058123 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66390017 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.6578366 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.66188076 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.544061219 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 3.78161173 > 11.5 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-06-26 04:24 0.762 10
2026-06-26 04:27 0.762 10
2026-07-09 12:00 1.199 10