Serial lookup
Search a serial number to see its full test history.
Serial 002421433
Tests4
Approved0
Failures4
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-06-22 18:48 | 75692 | 639177508919363436-9885 | S0001055 | Fail | View |
| 2026-06-22 19:09 | 75707 | 639177521709814896-5663 | S0001055 | Fail | View |
| 2026-07-09 12:35 | 77642 | 639191973354445962-9590 | S0001055 | Fail | View |
| 2026-07-09 12:36 | 77643 | 639191973547863439-4519 | S0001055 | Fail | View |
Test 75692
- Result
- Fail
- Date
- 2026-06-22 18:48
- Article
- S0001055
- ID record
- 639177508919363436-9885
- ID production
- 52269
- Temperature
- 28.98
- Humidity
- 46.61
- Test duration
- 12
- Error ID
- 115
- Error text
- DMM: Měření napětí: +5V (TP49/TP7)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 0.780766995 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 1002.23863 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.003133823 | < | 0.005 | Pass |
| 3.3 | R11.12: Zapnutí (TP42/TP43) | Pass | |||
| 3.4 | NZ3.1: Měření napětí: Zkrat? | 28.00651 | > | 27.9 | Pass |
| 3.5 | NZ3.1: Měření proudu: Kontrola odběru | 0.02234432 | < | 0.04 | Pass |
| 4.1 | DMM: Měření napětí: +BATT (TP49/TP44) | 27.9721028 | 27.9 | 28.1 | Pass |
| 4.2 | DMM: Měření napětí: +BATT (TP49/TP34) | 27.9954533 | 27.9 | 28.1 | Pass |
| 4.3 | DMM: Měření napětí: +12V (TP49/TP46) | 11.8360236 | 11 | 12.2 | Pass |
| 4.4 | DMM: Měření napětí: +5V (TP49/TP7) | 3.29719052 | 4.9 | 5.1 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (4)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-06-22 18:48 | 0.781 | — | 10 |
| 2026-06-22 19:09 | 0.772 | — | 10 |
| 2026-07-09 12:35 | 1.086 | — | 10 |
| 2026-07-09 12:36 | 1.096 | — | 10 |