Serial 002421638

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-06-22 15:59 75606 639177407889279234-7113 S0001055 Fail View
2026-06-22 17:30 75648 639177462357392190-7048 S0001055 Fail View
2026-07-09 12:43 77648 639191977564918225-6092 S0001055 Pass View

Test 75648

Result
Fail
Date
2026-06-22 17:30
Article
S0001055
ID record
639177462357392190-7048
ID production
52269
Temperature
28.04
Humidity
47.98
Test duration
3
Error ID
081
Error text
DMM: Kontrola hodnoty Odporu (TP6/TP4)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 9.9E+37 < 10 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-06-22 15:59 99000000000000000000000000000000000000 10
2026-06-22 17:30 99000000000000000000000000000000000000 10
2026-07-09 12:43 1.536 10