Serial 002421531

Tests2
Approved1
Failures1

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-06-22 16:40 75630 639177431938713437-5754 S0001055 Fail View
2026-06-22 17:49 75660 639177472929122926-1777 S0001055 Pass View

Test 75630

Result
Fail
Date
2026-06-22 16:40
Article
S0001055
ID record
639177431938713437-5754
ID production
52269
Temperature
28.18
Humidity
48.23
Test duration
17
Error ID
142
Error text
DMM: Měření napětí: (TP49/TP46)

Measurement lines

StepNameValueMinMaxResult
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0.768567373 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 1000.48713 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0.002367643 < 0.005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28.00651 > 27.9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0.02522928 < 0.04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27.9555789 27.9 28.1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27.9950032 27.9 28.1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11.9009004 11 12.2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4.98174695 4.9 5.1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3.30915954 3.2 3.4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3.3091702 3.2 3.4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4.66378065 4.57 4.77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4.66036967 4.57 4.77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4.6599003 4.57 4.77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0.547881874 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11.4279026 > 11.5 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (2)
DateValueMinMax
2026-06-22 16:40 0.769 10
2026-06-22 17:49 0.76 10