Serial C00R00002

Tests9
Approved5
Failures4

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-12-12 14:19 23698 639011458971929519-9245 S0003591 Pass View
2026-02-11 09:30 52537 639063990044855747-7288 S0003591 Fail View
2026-02-11 09:33 52540 639063991442490940-6727 S0003591 Pass View
2026-02-11 09:33 52542 639063992169628882-8944 S0003591 Fail View
2026-02-11 09:35 52544 639063992896943265-9689 S0003591 Pass View
2026-02-19 10:45 53489 639070946801537049-3104 S0003591 Pass View
2026-06-19 08:32 74910 639174547508020556-7642 S0003591 Fail View
2026-06-19 08:37 74913 639174549726996490-7219 S0003591 Fail View
2026-06-19 08:41 74920 639174552180744100-8222 S0003591 Pass View

Test 74913

Result
Fail
Date
2026-06-19 08:37
Article
S0003591
ID record
639174549726996490-7219
ID production
Temperature
Humidity
Test duration
52
Error ID
324
Error text
DMM: Měření zkratu: Audio (TP31/TP35) SHORT

Measurement lines

StepNameValueMinMaxResult
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 998.95088 950 1050 Pass
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5614.311 5320 5880 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.795195258 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.995271562 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1204727.71 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.15686544 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29499584 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28841385 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.29360306 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79891984 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.9876878 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.0207852 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9919491 11.4 12.6 Pass
3.2.1 DMM: Měření frekvence: 1kHz (TP2/TP17) 1000.01323 999.8 1000.2 Pass
3.3.6 DMM: Měření proudu: LEDG (TP25/TP27) 5.44673221E-08 < 0.0005 Pass
3.3.5 DMM: Měření proudu: LEDG (TP25/TP27) 0.0354183288 0.015 0.05 Pass
3.3.3 DMM: Měření proudu: LEDR (TP25/TP27) 6.09786409E-08 < 0.0005 Pass
3.3.4 DMM: Měření proudu: LEDG (TP25/TP27) -5.63283341E-08 < 0.0005 Pass
3.3.2 DMM: Měření proudu: LEDR (TP25/TP27) 0.0349642115 0.015 0.05 Pass
3.3.1 DMM: Měření proudu: LEDR (TP25/TP27) -6.49823147E-08 < 0.0005 Pass
3.4.1 DMM: Měření proudu: (TP29/TP27) 0.000979864098 < 0.0013 Pass
3.4.2 DMM: Měření proudu: (TP34/TP27) 0.000983717198 < 0.0013 Pass
3.5.1 NZ3.1: Měření proudu: Kontrola odběru 0.005132985 < 0.01 Pass
3.5.2 NZ3.1: Měření proudu: Kontrola odběru 0.005165558 < 0.01 Pass
3.6.1 DMM: Měření zkratu: RE5 - NC (TP43/TP42) OPEN 9.9E+37 > 1000000 Pass
3.6.2 DMM: Měření zkratu: RE5 - NC (TP43/TP42) SHORT 0.346456332 < 1 Pass
3.6.3 DMM: Měření zkratu: RE5 - NC (TP43/TP42) OPEN 9.9E+37 > 1000000 Pass
3.6.4 DMM: Měření zkratu: RE6 - BE (TP45/TP44) OPEN 9.9E+37 > 1000000 Pass
3.6.5 DMM: Měření zkratu: RE6 - BE (TP45/TP44) SHORT 0.336818203 < 1 Pass
3.6.6 DMM: Měření zkratu: RE6 - BE (TP45/TP44) OPEN 9.9E+37 > 1000000 Pass
3.7.1 DMM: Měření zkratu: Audio (TP37/TP32) SHORT 0.454206413 < 1 Pass
3.7.2 DMM: Měření zkratu: Audio (TP37/TP33) SHORT 0.492070493 < 1 Pass
3.7.3 DMM: Měření zkratu: Audio (TP31/TP35) SHORT 1.21604891 < 1 Fail

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-06-19 08:32 999.016 950 1050
2026-06-19 08:37 998.951 950 1050
2026-06-19 08:41 998.952 950 1050