Serial C01R00002

Tests12
Approved3
Failures9

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2025-12-11 14:50 23328 639010614176010688-1632 S0003590 Fail View
2025-12-11 14:51 23329 639010614616220679-6748 S0003590 Fail View
2025-12-11 14:54 23331 639010615436057208-2096 S0003590 Fail View
2025-12-11 14:57 23332 639010617152904047-3909 S0003590 Fail View
2025-12-11 14:57 23333 639010618499781928-4824 S0003590 Fail View
2025-12-11 15:14 23335 639010627903341318-6008 S0003590 Fail View
2025-12-11 15:15 23336 639010628722768229-3112 S0003590 Pass View
2026-02-19 09:45 53463 639070910846388478-2622 S0003590 Fail View
2026-02-19 09:45 53464 639070911409859225-2707 S0003590 Fail View
2026-02-19 09:46 53465 639070911839824534-5303 S0003590 Fail View
2026-02-19 09:49 53466 639070912814778161-9516 S0003590 Pass View
2026-06-19 06:59 74831 639174490728470061-8437 S0003590 Pass View

Test 74831

Result
Pass
Date
2026-06-19 06:59
Article
S0003590
ID record
639174490728470061-8437
ID production
Temperature
Humidity
Test duration
70
Error ID
Error text

Measurement lines

StepNameValueMinMaxResult
1.1.2 DMM: M??ení odporu: R2 (TP5/TP6) 998.223829 950 1050 Pass
1.1.1 DMM: M??ení odporu: R1 (TP5/TP4) 5605.47209 5320 5880 Pass
1.2.1 Kontrola vypo?ítaného pr?m?ru z odpor?: F1 (TP9/TP8) 1.042276 0 10 Pass
1.2.2 Kontrola vypo?ítaného pr?m?ru z odpor?: F2 (TP10/TP11) 0.77038 0 10 Pass
1.2.3 Kontrola vypo?ítaného pr?m?ru z odpor?: R3+R4 (TP10/TP8) 420509.557429 400000 460000 Pass
2.2.1 DMM: M??ení nap?tí: +3V3 LDO OUTPUT (TP2/TP13) 3.27802058 3.1 3.4 Pass
2.2.2 DMM: M??ení nap?tí: +3V3 Modem AVCC (TP2/TP15) 3.27221254 3.1 3.4 Pass
2.2.3 DMM: M??ení nap?tí: +3V3 VDDA (TP2/TP24) 3.27759436 3.1 3.4 Pass
2.2.4 DMM: M??ení nap?tí: +1V8 Audio (TP2/TP26) 1.80060718 1.74 1.86 Pass
2.3.1 DMM: M??ení nap?tí: +12V ACDC m?ni? (TP2/TP12) 11.9436099 11.7 12.3 Pass
3.2.1 DMM: M??ení frekvence: 1kHz (TP2/TP16) 1000.00806 999.8 1000.2 Pass
3.3.1 NZ3.2: M??ení proudu: Kontrola odb?ru 0.005089924 < 0.02 Pass
3.3.2 NZ3.2: M??ení proudu: Kontrola odb?ru 0.0050869 < 0.2 Pass
3.4.1 DMM: M??ení odporu: (TP33/TP32) 9.9E+37 > 10000000 Pass
3.4.2 DMM: M??ení odporu: (TP33/TP32) 0.414028758 < 7 Pass
3.4.3 DMM: M??ení odporu: (TP35/TP34) 9.9E+37 > 10000000 Pass
3.4.4 DMM: M??ení odporu: (TP35/TP34) 0.519655019 < 7 Pass
3.4.5 DMM: M??ení odporu: (TP37/TP36) 9.9E+37 > 10000000 Pass
3.4.6 DMM: M??ení odporu: (TP37/TP36) 0.508435237 < 7 Pass
3.4.7 DMM: M??ení odporu: (TP39/TP40) 9.9E+37 > 10000000 Pass
3.4.8 DMM: M??ení odporu: (TP39/TP40) 115.882407 90 150 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2026-06-19 06:59 998.224 950 1050