Serial lookup
Search a serial number to see its full test history.
Serial 001966356
Tests6
Approved0
Failures6
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2025-06-19 14:27 | 19421 | 638859328203610903-4852 | Fail | View | |
| 2025-07-29 07:18 | 22779 | 638893631132494649-7769 | Fail | View | |
| 2025-08-27 10:33 | 48029 | 638918804193490559-5062 | Fail | View | |
| 2025-08-27 10:36 | 48030 | 638918805726835969-3149 | Fail | View | |
| 2026-02-02 06:59 | 60977 | 639056087852283490-3859 | S0001604 | Fail | View |
| 2026-02-02 07:00 | 60978 | 639056088164953694-5207 | S0001604 | Fail | View |
Test 60977
- Result
- Fail
- Date
- 2026-02-02 06:59
- Article
- S0001604
- ID record
- 639056087852283490-3859
- ID production
- 52627
- Temperature
- 24.26
- Humidity
- 22.35
- Test duration
- 3
- Error ID
- 059
- Error text
- NZ3: Měření proudu: (TP2/TP9)
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.0 | Dekódování a uložení načteného SN | 001966356 | Pass | ||
| 0.1 | Uložení čísla výrobního příkazu | 52627 | Pass | ||
| 0.2 | Uložení ID obsluhy | 1332 | Pass | ||
| 0.3 | Uložení teploty okolí | 24.26 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 22.35 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0001604 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP7/TP8) | 100.721613 | 95 | 105 | Pass |
| 2.1 | NZ3: Měření proudu: (TP2/TP9) | 0.008283506 | 0.002 | 0.008 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (2)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-02-02 06:59 | 1966356 | — | — |
| 2026-02-02 07:00 | 1966356 | — | — |