Serial 001791579

Tests26
Approved0
Failures26

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-04 14:18 117 638610491010391758-7082 S0001055 Fail View
2024-09-04 14:45 118 638610506974024329-1251 S0001055 Fail View
2024-09-04 14:56 119 638610513558362910-7362 S0001055 Fail View
2024-09-23 08:48 524 638626708553972701-4829 S0001055 Fail View
2024-12-05 15:08 5423 638690044640990310-1385 S0001055 Fail View
2024-12-05 15:24 5424 638690054090776328-4412 S0001055 Fail View
2025-09-05 11:32 25772 638926615087314204-9021 S0001055 Fail View
2025-11-06 17:25 40594 638980430860671035-2619 S0001055 Fail View
2026-07-09 15:02 77754 639192061011499505-1916 S0001055 Fail View
2026-07-09 15:02 77755 639192061503487785-9949 S0001055 Fail View
2026-07-09 15:05 77756 639192062885456120-7661 S0001055 Fail View
2026-07-09 15:44 77785 639192086590841204-9526 S0001055 Fail View
2026-08-11 04:57 81275 639220209806147612-1733 S0001055 Fail View
2026-08-11 04:57 81276 639220210442951964-9514 S0001055 Fail View
2026-08-11 04:58 81277 639220210750082046-3964 S0001055 Fail View
2026-09-23 05:14 86086 639257372649206631-6164 S0001055 Fail View
2026-09-23 05:15 86087 639257373282538885-1747 S0001055 Fail View
2026-09-23 05:16 86088 639257373681161380-8130 S0001055 Fail View
2026-09-23 05:25 86093 639257379250356497-3217 S0001055 Fail View
2026-09-23 05:32 86098 639257383081671968-1274 S0001055 Fail View
2026-09-23 05:32 86099 639257383338221827-9069 S0001055 Fail View
2026-09-23 05:34 86100 639257384037053788-2817 S0001055 Fail View
2026-09-23 05:36 86101 639257385234025505-4942 S0001055 Fail View
2026-09-23 05:38 86102 639257386543478842-9631 S0001055 Fail View
2026-09-23 05:44 86103 639257390023852283-1687 S0001055 Fail View
2026-09-23 05:45 86104 639257390762551602-3218 S0001055 Fail View

Test 5424

Result
Fail
Date
2024-12-05 15:24
Article
S0001055
ID record
638690054090776328-4412
ID production
49267
Temperature
25,61
Humidity
29,19
Test duration
54
Error ID
358
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 25,61 Pass
0.4 Uložení vlhkosti okolí 29,19 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,595456632 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 995,967958 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,000334296 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02369101 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9699822 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,9974048 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,8404413 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4,99365997 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,3070026 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,30700244 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,67579255 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,67211178 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,67124113 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,53377328 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,7583878 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02507602 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2,024054 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,64927 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,2640183 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,62591579 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,02509076 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3827 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2026 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2026 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2013 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2028 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2027 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,30261961 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,00348338011 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,30383122 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,00346891537 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,30244298 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,0035925029 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,302602 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,0034917769 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 61 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995,0138 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995,0119 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14,0036227 13,3 14,7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995,01 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995,0119 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14,0122413 13,3 14,7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995,0081 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995,0123 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14,0099045 13,3 14,7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0,00183549319 < 0,5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2256 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2263 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2261 Pass
20.0.5 Analysis: VA VA[2256] 2210 2340 Pass
20.0.6 Analysis: VB VB[2263] 2210 2340 Pass
20.0.7 Analysis: VC VC[2261] 2210 2340 Pass
20.1.3 TestSW: [ADC_PA1] sense B 2101 1998[VB] 2098[VB] Fail
20.1.2 TestSW: [ADC_PA0] sense A 2423 2421[VA] 2521[VA] Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989872 4,7 5,3 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0,03759718 < 0,06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (18)
DateValueMinMax
2026-07-09 15:02 1.001 10
2026-07-09 15:02 0.972 10
2026-07-09 15:05 0.962 10
2026-07-09 15:44 0.957 10
2026-08-11 04:57 0.769 10
2026-08-11 04:57 0.759 10
2026-08-11 04:58 0.75 10
2026-09-23 05:14 0.784 10
2026-09-23 05:15 0.777 10
2026-09-23 05:16 0.978 10
2026-09-23 05:25 0.933 10
2026-09-23 05:32 0.802 10
2026-09-23 05:32 0.784 10
2026-09-23 05:34 0.798 10
2026-09-23 05:36 0.777 10
2026-09-23 05:38 0.777 10
2026-09-23 05:44 0.782 10
2026-09-23 05:45 0.782 10