Serial lookup
Search a serial number to see its full test history.
Serial 001791579
Tests26
Approved0
Failures26
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2024-09-04 14:18 | 117 | 638610491010391758-7082 | S0001055 | Fail | View |
| 2024-09-04 14:45 | 118 | 638610506974024329-1251 | S0001055 | Fail | View |
| 2024-09-04 14:56 | 119 | 638610513558362910-7362 | S0001055 | Fail | View |
| 2024-09-23 08:48 | 524 | 638626708553972701-4829 | S0001055 | Fail | View |
| 2024-12-05 15:08 | 5423 | 638690044640990310-1385 | S0001055 | Fail | View |
| 2024-12-05 15:24 | 5424 | 638690054090776328-4412 | S0001055 | Fail | View |
| 2025-09-05 11:32 | 25772 | 638926615087314204-9021 | S0001055 | Fail | View |
| 2025-11-06 17:25 | 40594 | 638980430860671035-2619 | S0001055 | Fail | View |
| 2026-07-09 15:02 | 77754 | 639192061011499505-1916 | S0001055 | Fail | View |
| 2026-07-09 15:02 | 77755 | 639192061503487785-9949 | S0001055 | Fail | View |
| 2026-07-09 15:05 | 77756 | 639192062885456120-7661 | S0001055 | Fail | View |
| 2026-07-09 15:44 | 77785 | 639192086590841204-9526 | S0001055 | Fail | View |
| 2026-08-11 04:57 | 81275 | 639220209806147612-1733 | S0001055 | Fail | View |
| 2026-08-11 04:57 | 81276 | 639220210442951964-9514 | S0001055 | Fail | View |
| 2026-08-11 04:58 | 81277 | 639220210750082046-3964 | S0001055 | Fail | View |
| 2026-09-23 05:14 | 86086 | 639257372649206631-6164 | S0001055 | Fail | View |
| 2026-09-23 05:15 | 86087 | 639257373282538885-1747 | S0001055 | Fail | View |
| 2026-09-23 05:16 | 86088 | 639257373681161380-8130 | S0001055 | Fail | View |
| 2026-09-23 05:25 | 86093 | 639257379250356497-3217 | S0001055 | Fail | View |
| 2026-09-23 05:32 | 86098 | 639257383081671968-1274 | S0001055 | Fail | View |
| 2026-09-23 05:32 | 86099 | 639257383338221827-9069 | S0001055 | Fail | View |
| 2026-09-23 05:34 | 86100 | 639257384037053788-2817 | S0001055 | Fail | View |
| 2026-09-23 05:36 | 86101 | 639257385234025505-4942 | S0001055 | Fail | View |
| 2026-09-23 05:38 | 86102 | 639257386543478842-9631 | S0001055 | Fail | View |
| 2026-09-23 05:44 | 86103 | 639257390023852283-1687 | S0001055 | Fail | View |
| 2026-09-23 05:45 | 86104 | 639257390762551602-3218 | S0001055 | Fail | View |
Test 5423
- Result
- Fail
- Date
- 2024-12-05 15:08
- Article
- S0001055
- ID record
- 638690044640990310-1385
- ID production
- 49267
- Temperature
- 25,69
- Humidity
- 28,79
- Test duration
- 54
- Error ID
- 358
- Error text
- TestSW: [ADC_PA1] sense B
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 0.3 | Uložení teploty okolí | 25,69 | Pass | ||
| 0.4 | Uložení vlhkosti okolí | 28,79 | Pass | ||
| 0.5 | Uložení Id testeru (uloženo na lokálním disku) | Vez_Hokami_01-v01.01 | Pass | ||
| 0.6 | Uložení id Artiklu (produktové číslo) | S0001055 | Pass | ||
| 1.1 | DMM: Kontrola hodnoty Odporu (TP6/TP4) | 0,600409371 | < | 10 | Pass |
| 1.2 | DMM: Kontrola hodnoty Odporu (TP6/TP5) | 995,99026 | 800 | 1200 | Pass |
| 3.1 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 3.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,0007615888 | < | 0,005 | Pass |
| 3.3 | R11.12: Zapnutí (TP42/TP43) | Pass | |||
| 3.4 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 3.5 | NZ3.1: Měření proudu: Kontrola odběru | 0,02393559 | < | 0,04 | Pass |
| 4.1 | DMM: Měření napětí: +BATT (TP49/TP44) | 27,9694675 | 27,9 | 28,1 | Pass |
| 4.2 | DMM: Měření napětí: +BATT (TP49/TP34) | 27,9967944 | 27,9 | 28,1 | Pass |
| 4.3 | DMM: Měření napětí: +12V (TP49/TP46) | 11,8413084 | 11 | 12,2 | Pass |
| 4.4 | DMM: Měření napětí: +5V (TP49/TP7) | 4,99363226 | 4,9 | 5,1 | Pass |
| 4.5 | DMM: Měření napětí: +3V3 (TP49/TP16) | 3,30694764 | 3,2 | 3,4 | Pass |
| 4.6 | DMM: Měření napětí: VDDA +3V3 (TP49/TP2) | 3,30695252 | 3,2 | 3,4 | Pass |
| 4.7 | DMM: Měření napětí: (TP49/TP8) | 4,67576205 | 4,57 | 4,77 | Pass |
| 4.8 | DMM: Měření napětí: (TP49/TP9) | 4,67208939 | 4,57 | 4,77 | Pass |
| 4.9 | DMM: Měření napětí: (TP49/TP10) | 4,67121345 | 4,57 | 4,77 | Pass |
| 5.1 | DMM: Měření napětí: (TP49/TP46) | 0,530317502 | < | 1 | Pass |
| 5.2 | DMM: Měření napětí: (TP49/TP46) | 11,7587804 | > | 11,5 | Pass |
| 6.1 | R9.12: Vypnutí (TP49/TP28) | Pass | |||
| 7.1 | NZ3: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 7.2 | NZ3: Měření proudu: Kontrola odběru | 0,02515264 | < | 0,06 | Pass |
| 7.3 | R0.6: Zapnutí Ext. Programátoru | Pass | |||
| 8.1 | TestSw: Ověření komunikace | [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: | Pass | ||
| 9.1 | TestSW: [CHG_SIG (PC14)] = log1? | 16384 | 16384 | 16384 | Pass |
| 9.2 | EL1.1: Ověření proudu na zátěži -> Current? | 2,022019 | 1,6 | 2,8 | Pass |
| 9.3 | DMM: Měření napětí: Vstup U14 (TP39/TP32) | 29,648933 | 29 | 30,1 | Pass |
| 9.4 | DMM: Měření napětí: Vstup U14 (TP39/TP33) | 11,2730423 | 10,8 | 11,5 | Pass |
| 9.5 | DMM: Měření napětí: Vstup U14 (TP39/TP40) | 1,6219585 | 1,5 | 1,8 | Pass |
| 10.1 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 10.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,02491689 | < | 0,06 | Pass |
| 10.3 | TestSW: [ADC_PA03] | 3827 | 3667 | 3937 | Pass |
| 12.1 | TestSW: [PA15] - napájení sense ABC | Pass | |||
| 12.2 | TestSW: [HALL_A (PB4)] = log0? | 0 | 0 | 0 | Pass |
| 12.3 | TestSW: [HALL_A (PB4)] = log1? | 16 | 16 | 16 | Pass |
| 12.4 | TestSW: [HALL_B (PB5)] = log0? | 0 | 0 | 0 | Pass |
| 12.5 | TestSW: [HALL_B (PB5)] = log1? | 32 | 32 | 32 | Pass |
| 12.6 | TestSW: [HALL_C (PB0)] = log0? | 0 | 0 | 0 | Pass |
| 12.7 | TestSW: [HALL_C (PB0)] = log1? | 1 | 1 | 1 | Pass |
| 13.1 | TestSW: [CON_ID (PC13)] = log1? | 8192 | 8192 | 8192 | Pass |
| 13.10 | TestSW: [BTN_FFWD][ADC_PA6]? | 4085 | 4000 | 4096 | Pass |
| 13.11 | TestSW: [BTN_FFWD][ADC_PA6]? | 2025 | 1900 | 2100 | Pass |
| 13.12 | TestSW: [BTN_STOP][ADC_PA5]? | 4085 | 4000 | 4096 | Pass |
| 13.13 | TestSW: [BTN_STOP][ADC_PA5]? | 2027 | 1900 | 2100 | Pass |
| 13.2 | TestSW: [CON_ID (PC13)] = log0? | 0 | 0 | 0 | Pass |
| 13.3 | TestSW: [BTN_DRV][PA11] na log1 | Pass | |||
| 13.4 | TestSW: [BTN_FWD][ADC_PB1]? | 4084 | 4000 | 4096 | Pass |
| 13.5 | TestSW: [BTN_FWD][ADC_PB1]? | 2013 | 1900 | 2100 | Pass |
| 13.6 | TestSW: [BTN_REV][ADC_PA4]? | 4085 | 4000 | 4096 | Pass |
| 13.7 | TestSW: [BTN_REV][ADC_PA4]? | 2027 | 1900 | 2100 | Pass |
| 13.8 | TestSW: [BTN_ULCK][ADC_PA7]? | 4085 | 4000 | 4096 | Pass |
| 13.9 | TestSW: [BTN_ULCK][ADC_PA7]? | 2027 | 1900 | 2100 | Pass |
| 14.1 | TestSW: [LED1][PB2] na log1 | Pass | |||
| 14.10 | DMM: Měření napětí: LED3 (TP49/TP14) | 3,30259887 | > | 3 | Pass |
| 14.11 | TestSW: [LED3][PB11] na log0 | Pass | |||
| 14.12 | DMM: Měření napětí: LED3 (TP49/TP14) | 0,00347759924 | < | 0,1 | Pass |
| 14.13 | TestSW: [LED4][PB12] na log1 | Pass | |||
| 14.14 | DMM: Měření napětí: LED4 (TP49/TP12) | 3,30380762 | > | 3 | Pass |
| 14.15 | TestSW: [LED4][PB12] na log0 | Pass | |||
| 14.16 | DMM: Měření napětí: LED4 (TP49/TP12) | 0,00347226122 | < | 0,1 | Pass |
| 14.2 | DMM: Měření napětí: LED1 (TP49/TP13) | 3,30242908 | > | 3 | Pass |
| 14.3 | TestSW: [LED1][PB2] na log0 | Pass | |||
| 14.4 | DMM: Měření napětí: LED1 (TP49/TP13) | 0,00358906423 | < | 0,1 | Pass |
| 14.5 | TestSW: [LED2][PB10] na log1 | Pass | |||
| 14.6 | DMM: Měření napětí: LED1 (TP49/TP11) | 3,30257171 | > | 3 | Pass |
| 14.7 | TestSW: [LED2][PB10] na log0 | Pass | |||
| 14.8 | DMM: Měření napětí: LED1 (TP49/TP11) | 0,00348507883 | < | 0,1 | Pass |
| 14.9 | TestSW: [LED3][PB11] na log1 | Pass | |||
| 15.1 | TestSW: ntc | 62 | 49 | 90 | Pass |
| 16.1 | DMM: Měření frekvence (TP49/TP55) | 19995,0138 | 19600 | 20400 | Pass |
| 16.2 | DMM: Měření frekvence (TP49/TP56) | 19995,0138 | 19600 | 20400 | Pass |
| 16.3 | DMM: Měření napětí (TP49/TP52) | 14,0033873 | 13,3 | 14,7 | Pass |
| 17.1 | DMM: Měření frekvence (TP49/TP61) | 19995,0085 | 19600 | 20400 | Pass |
| 17.2 | DMM: Měření frekvence (TP49/TP62) | 19995,0119 | 19600 | 20400 | Pass |
| 17.3 | DMM: Měření napětí (TP49/TP58) | 14,0121504 | 13,3 | 14,7 | Pass |
| 18.1 | DMM: Měření frekvence (TP49/TP67) | 19995,0081 | 19600 | 20400 | Pass |
| 18.2 | DMM: Měření frekvence (TP49/TP68) | 19995,0119 | 19600 | 20400 | Pass |
| 18.3 | DMM: Měření napětí (TP49/TP58) | 14,0098287 | 13,3 | 14,7 | Pass |
| 19.1 | DMM: Měření napětí: +5V (TP49/TP7) | -0,00209836316 | < | 0,5 | Pass |
| 20.0.1 | TestSW: [ADC_PA0] sense A do var | VA = 2256 | Pass | ||
| 20.0.2 | TestSW: [ADC_PA1] sense B do var | VB = 2263 | Pass | ||
| 20.0.3 | TestSW: [ADC_PA2] sense C do var | VC = 2261 | Pass | ||
| 20.0.5 | Analysis: VA | VA[2256] | 2210 | 2340 | Pass |
| 20.0.6 | Analysis: VB | VB[2263] | 2210 | 2340 | Pass |
| 20.0.7 | Analysis: VC | VC[2261] | 2210 | 2340 | Pass |
| 20.1.3 | TestSW: [ADC_PA1] sense B | 2101 | 1998[VB] | 2098[VB] | Fail |
| 20.1.2 | TestSW: [ADC_PA0] sense A | 2424 | 2421[VA] | 2521[VA] | Pass |
| 20.1.1 | EL1.2: Ověření proudu na zátěži -> Current? | 4,989622 | 4,7 | 5,3 | Pass |
| 20.1 | NZ3.1: Měření napětí: Zkrat? | 28,00851 | > | 27,9 | Pass |
| 20.2 | NZ3.1: Měření proudu: Kontrola odběru | 0,03762665 | < | 0,06 | Pass |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (18)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-07-09 15:02 | 1.001 | — | 10 |
| 2026-07-09 15:02 | 0.972 | — | 10 |
| 2026-07-09 15:05 | 0.962 | — | 10 |
| 2026-07-09 15:44 | 0.957 | — | 10 |
| 2026-08-11 04:57 | 0.769 | — | 10 |
| 2026-08-11 04:57 | 0.759 | — | 10 |
| 2026-08-11 04:58 | 0.75 | — | 10 |
| 2026-09-23 05:14 | 0.784 | — | 10 |
| 2026-09-23 05:15 | 0.777 | — | 10 |
| 2026-09-23 05:16 | 0.978 | — | 10 |
| 2026-09-23 05:25 | 0.933 | — | 10 |
| 2026-09-23 05:32 | 0.802 | — | 10 |
| 2026-09-23 05:32 | 0.784 | — | 10 |
| 2026-09-23 05:34 | 0.798 | — | 10 |
| 2026-09-23 05:36 | 0.777 | — | 10 |
| 2026-09-23 05:38 | 0.777 | — | 10 |
| 2026-09-23 05:44 | 0.782 | — | 10 |
| 2026-09-23 05:45 | 0.782 | — | 10 |