Serial 001791563

Tests16
Approved0
Failures16

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-09 09:25 314 638614634765678713-9201 S0001055 Fail View
2024-09-09 09:32 315 638614639338165882-7606 S0001055 Fail View
2024-09-09 09:54 316 638614651878217729-1702 S0001055 Fail View
2024-09-09 10:08 317 638614660586133595-5269 S0001055 Fail View
2024-09-23 09:11 516 638626722510725967-2507 S0001055 Fail View
2024-09-24 14:51 553 638627790017530403-2609 S0001055 Fail View
2024-12-05 15:04 5413 638690042408951515-5537 S0001055 Fail View
2024-12-05 15:26 5414 638690055457018875-4409 S0001055 Fail View
2025-09-05 11:25 25767 638926610640555499-9837 S0001055 Fail View
2025-11-06 17:28 40591 638980432573811170-4849 S0001055 Fail View
2026-07-09 14:51 77747 639192054299298921-6972 S0001055 Fail View
2026-07-09 14:52 77748 639192054931394286-5596 S0001055 Fail View
2026-08-11 04:38 81268 639220198731292262-1414 S0001055 Fail View
2026-08-11 04:39 81269 639220199356987223-4396 S0001055 Fail View
2026-09-23 05:24 86091 639257378295154043-1674 S0001055 Fail View
2026-09-23 05:50 86106 639257393671081066-5914 S0001055 Fail View

Test 5413

Result
Fail
Date
2024-12-05 15:04
Article
S0001055
ID record
638690042408951515-5537
ID production
49267
Temperature
25,65
Humidity
29,15
Test duration
54
Error ID
358
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 25,65 Pass
0.4 Uložení vlhkosti okolí 29,15 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,584110614 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 999,330754 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,0006407681 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02417134 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9706653 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,9970965 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,9014166 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4,98731767 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,3092711 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,30927967 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,668458 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,66484611 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,66627998 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,523777071 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,8263653 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02557699 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2,023751 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,653398 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,2505802 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,59373548 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,02550626 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3835 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4085 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2025 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4085 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2024 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2024 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2028 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,30497168 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,0035041099 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,30627369 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,00348510855 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,30475136 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,00374839675 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,30492517 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,00351894411 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 58 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995,0029 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995,0044 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14,0096319 13,3 14,7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19994,9972 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995,0025 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14,0009313 13,3 14,7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19994,9968 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995,001 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14,0081899 13,3 14,7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0,00172212832 < 0,5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2256 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2255 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2256 Pass
20.0.5 Analysis: VA VA[2256] 2210 2340 Pass
20.0.6 Analysis: VB VB[2255] 2210 2340 Pass
20.0.7 Analysis: VC VC[2256] 2210 2340 Pass
20.1.3 TestSW: [ADC_PA1] sense B 2092 1990[VB] 2090[VB] Fail
20.1.2 TestSW: [ADC_PA0] sense A 2423 2421[VA] 2521[VA] Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989706 4,7 5,3 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0,03794786 < 0,06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (6)
DateValueMinMax
2026-07-09 14:51 0.98 10
2026-07-09 14:52 0.973 10
2026-08-11 04:38 0.79 10
2026-08-11 04:39 0.778 10
2026-09-23 05:24 0.834 10
2026-09-23 05:50 0.801 10