Testing Portal everyone (auth disabled)

Serial lookup

Search a serial number to see its full test history.

Serial 001791561

Tests14
Approved0
Failures14

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-09 09:19 309 638614631319446649-1787 S0001055 Fail View
2024-09-09 09:45 310 638614646419318352-2437 S0001055 Fail View
2024-09-23 09:13 514 638626723320612033-3332 S0001055 Fail View
2024-09-24 14:49 552 638627789067135836-6208 S0001055 Fail View
2024-12-05 15:07 5409 638690043906116501-2269 S0001055 Fail View
2024-12-05 15:25 5410 638690054762700318-6118 S0001055 Fail View
2025-09-05 11:30 25765 638926613812984827-1487 S0001055 Fail View
2025-11-06 17:31 40589 638980434203881006-6312 S0001055 Fail View
2026-07-09 15:09 77757 639192064896193009-2270 S0001055 Fail View
2026-07-09 15:42 77783 639192085150625986-8792 S0001055 Fail View
2026-07-09 15:43 77784 639192085817614456-2814 S0001055 Fail View
2026-08-11 04:36 81266 639220197070362250-7252 S0001055 Fail View
2026-08-11 04:37 81267 639220197713336807-1676 S0001055 Fail View
2026-09-23 05:48 86105 639257392645690799-4576 S0001055 Fail View

Test 5409

Result
Fail
Date
2024-12-05 15:07
Article
S0001055
ID record
638690043906116501-2269
ID production
49267
Temperature
25,69
Humidity
28,79
Test duration
54
Error ID
358
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 25,69 Pass
0.4 Uložení vlhkosti okolí 28,79 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,58684295 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 995,56418 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,0007144393 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02419197 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9721614 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,9971905 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,87333 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4,9663325 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,30781344 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,30782559 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,65086612 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,64604826 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,64628186 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,525279708 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,7837872 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02524399 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2,074807 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,6454034 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,2798999 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,61020887 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,02517032 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3846 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2026 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4086 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2027 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4084 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2014 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4085 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2026 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4086 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2028 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,30378947 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,00347160851 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,30501259 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,00346989013 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,30363497 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,00356180023 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,3036587 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,00348384 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 60 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995,0349 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995,0326 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14,010094 13,3 14,7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995,0255 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995,0293 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14,0077919 13,3 14,7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995,0274 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995,0289 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14,0140321 13,3 14,7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) -0,00234046708 < 0,5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2253 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2242 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2248 Pass
20.0.5 Analysis: VA VA[2253] 2210 2340 Pass
20.0.6 Analysis: VB VB[2242] 2210 2340 Pass
20.0.7 Analysis: VC VC[2248] 2210 2340 Pass
20.1.3 TestSW: [ADC_PA1] sense B 2080 1977[VB] 2077[VB] Fail
20.1.2 TestSW: [ADC_PA0] sense A 2420 2418[VA] 2518[VA] Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4,98978 4,7 5,3 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0,03791544 < 0,06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (6)
DateValueMinMax
2026-07-09 15:09 1.005 10
2026-07-09 15:42 1.014 10
2026-07-09 15:43 0.965 10
2026-08-11 04:36 0.84 10
2026-08-11 04:37 0.808 10
2026-09-23 05:48 0.843 10