Serial 001791508

Tests9
Approved1
Failures8

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2024-09-09 08:04 260 638614586146778992-9802 S0001055 Fail View
2024-09-09 08:24 261 638614598350729917-2167 S0001055 Fail View
2024-09-23 09:16 509 638626725077389919-7829 S0001055 Fail View
2024-09-24 15:11 546 638627802151673719-9948 S0001055 Fail View
2024-12-05 15:17 5401 638690049814161171-9057 S0001055 Fail View
2024-12-05 15:19 5402 638690051319283715-3375 S0001055 Fail View
2025-09-05 11:26 25762 638926611421264013-1623 S0001055 Fail View
2025-11-06 17:32 40586 638980434964616394-8442 S0001055 Fail View
2026-07-09 15:00 77753 639192059897788338-4070 S0001055 Pass View

Test 5401

Result
Fail
Date
2024-12-05 15:17
Article
S0001055
ID record
638690049814161171-9057
ID production
49267
Temperature
25,69
Humidity
28,31
Test duration
54
Error ID
358
Error text
TestSW: [ADC_PA1] sense B

Measurement lines

StepNameValueMinMaxResult
0.3 Uložení teploty okolí 25,69 Pass
0.4 Uložení vlhkosti okolí 28,31 Pass
0.5 Uložení Id testeru (uloženo na lokálním disku) Vez_Hokami_01-v01.01 Pass
0.6 Uložení id Artiklu (produktové číslo) S0001055 Pass
1.1 DMM: Kontrola hodnoty Odporu (TP6/TP4) 0,577569186 < 10 Pass
1.2 DMM: Kontrola hodnoty Odporu (TP6/TP5) 997,317494 800 1200 Pass
3.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.2 NZ3.1: Měření proudu: Kontrola odběru 0,0006643428 < 0,005 Pass
3.3 R11.12: Zapnutí (TP42/TP43) Pass
3.4 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
3.5 NZ3.1: Měření proudu: Kontrola odběru 0,02409767 < 0,04 Pass
4.1 DMM: Měření napětí: +BATT (TP49/TP44) 27,9761764 27,9 28,1 Pass
4.2 DMM: Měření napětí: +BATT (TP49/TP34) 27,9974978 27,9 28,1 Pass
4.3 DMM: Měření napětí: +12V (TP49/TP46) 11,8017698 11 12,2 Pass
4.4 DMM: Měření napětí: +5V (TP49/TP7) 4,99318412 4,9 5,1 Pass
4.5 DMM: Měření napětí: +3V3 (TP49/TP16) 3,30431691 3,2 3,4 Pass
4.6 DMM: Měření napětí: VDDA +3V3 (TP49/TP2) 3,30431225 3,2 3,4 Pass
4.7 DMM: Měření napětí: (TP49/TP8) 4,67408552 4,57 4,77 Pass
4.8 DMM: Měření napětí: (TP49/TP9) 4,67127521 4,57 4,77 Pass
4.9 DMM: Měření napětí: (TP49/TP10) 4,67070469 4,57 4,77 Pass
5.1 DMM: Měření napětí: (TP49/TP46) 0,531964066 < 1 Pass
5.2 DMM: Měření napětí: (TP49/TP46) 11,7135883 > 11,5 Pass
6.1 R9.12: Vypnutí (TP49/TP28) Pass
7.1 NZ3: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
7.2 NZ3: Měření proudu: Kontrola odběru 0,02523221 < 0,06 Pass
7.3 R0.6: Zapnutí Ext. Programátoru Pass
8.1 TestSw: Ověření komunikace [TYP:AA NAME:eDrive NAME2:TestSW HW:Kolecko v4 SW: Pass
9.1 TestSW: [CHG_SIG (PC14)] = log1? 16384 16384 16384 Pass
9.2 EL1.1: Ověření proudu na zátěži -> Current? 2,063583 1,6 2,8 Pass
9.3 DMM: Měření napětí: Vstup U14 (TP39/TP32) 29,6257683 29 30,1 Pass
9.4 DMM: Měření napětí: Vstup U14 (TP39/TP33) 11,2490114 10,8 11,5 Pass
9.5 DMM: Měření napětí: Vstup U14 (TP39/TP40) 1,57880618 1,5 1,8 Pass
10.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
10.2 NZ3.1: Měření proudu: Kontrola odběru 0,02523221 < 0,06 Pass
10.3 TestSW: [ADC_PA03] 3845 3667 3937 Pass
12.1 TestSW: [PA15] - napájení sense ABC Pass
12.2 TestSW: [HALL_A (PB4)] = log0? 0 0 0 Pass
12.3 TestSW: [HALL_A (PB4)] = log1? 16 16 16 Pass
12.4 TestSW: [HALL_B (PB5)] = log0? 0 0 0 Pass
12.5 TestSW: [HALL_B (PB5)] = log1? 32 32 32 Pass
12.6 TestSW: [HALL_C (PB0)] = log0? 0 0 0 Pass
12.7 TestSW: [HALL_C (PB0)] = log1? 1 1 1 Pass
13.1 TestSW: [CON_ID (PC13)] = log1? 8192 8192 8192 Pass
13.10 TestSW: [BTN_FFWD][ADC_PA6]? 4086 4000 4096 Pass
13.11 TestSW: [BTN_FFWD][ADC_PA6]? 2027 1900 2100 Pass
13.12 TestSW: [BTN_STOP][ADC_PA5]? 4086 4000 4096 Pass
13.13 TestSW: [BTN_STOP][ADC_PA5]? 2025 1900 2100 Pass
13.2 TestSW: [CON_ID (PC13)] = log0? 0 0 0 Pass
13.3 TestSW: [BTN_DRV][PA11] na log1 Pass
13.4 TestSW: [BTN_FWD][ADC_PB1]? 4085 4000 4096 Pass
13.5 TestSW: [BTN_FWD][ADC_PB1]? 2015 1900 2100 Pass
13.6 TestSW: [BTN_REV][ADC_PA4]? 4086 4000 4096 Pass
13.7 TestSW: [BTN_REV][ADC_PA4]? 2025 1900 2100 Pass
13.8 TestSW: [BTN_ULCK][ADC_PA7]? 4085 4000 4096 Pass
13.9 TestSW: [BTN_ULCK][ADC_PA7]? 2023 1900 2100 Pass
14.1 TestSW: [LED1][PB2] na log1 Pass
14.10 DMM: Měření napětí: LED3 (TP49/TP14) 3,29965884 > 3 Pass
14.11 TestSW: [LED3][PB11] na log0 Pass
14.12 DMM: Měření napětí: LED3 (TP49/TP14) 0,00347141889 < 0,1 Pass
14.13 TestSW: [LED4][PB12] na log1 Pass
14.14 DMM: Měření napětí: LED4 (TP49/TP12) 3,30091149 > 3 Pass
14.15 TestSW: [LED4][PB12] na log0 Pass
14.16 DMM: Měření napětí: LED4 (TP49/TP12) 0,00346074101 < 0,1 Pass
14.2 DMM: Měření napětí: LED1 (TP49/TP13) 3,29955328 > 3 Pass
14.3 TestSW: [LED1][PB2] na log0 Pass
14.4 DMM: Měření napětí: LED1 (TP49/TP13) 0,00364948819 < 0,1 Pass
14.5 TestSW: [LED2][PB10] na log1 Pass
14.6 DMM: Měření napětí: LED1 (TP49/TP11) 3,29965656 > 3 Pass
14.7 TestSW: [LED2][PB10] na log0 Pass
14.8 DMM: Měření napětí: LED1 (TP49/TP11) 0,00353235685 < 0,1 Pass
14.9 TestSW: [LED3][PB11] na log1 Pass
15.1 TestSW: ntc 60 49 90 Pass
16.1 DMM: Měření frekvence (TP49/TP55) 19995,0496 19600 20400 Pass
16.2 DMM: Měření frekvence (TP49/TP56) 19995,0477 19600 20400 Pass
16.3 DMM: Měření napětí (TP49/TP52) 14,0128238 13,3 14,7 Pass
17.1 DMM: Měření frekvence (TP49/TP61) 19995,042 19600 20400 Pass
17.2 DMM: Měření frekvence (TP49/TP62) 19995,0458 19600 20400 Pass
17.3 DMM: Měření napětí (TP49/TP58) 14,0142109 13,3 14,7 Pass
18.1 DMM: Měření frekvence (TP49/TP67) 19995,0406 19600 20400 Pass
18.2 DMM: Měření frekvence (TP49/TP68) 19995,0443 19600 20400 Pass
18.3 DMM: Měření napětí (TP49/TP58) 14,0129843 13,3 14,7 Pass
19.1 DMM: Měření napětí: +5V (TP49/TP7) 0,000822794974 < 0,5 Pass
20.0.1 TestSW: [ADC_PA0] sense A do var VA = 2265 Pass
20.0.2 TestSW: [ADC_PA1] sense B do var VB = 2261 Pass
20.0.3 TestSW: [ADC_PA2] sense C do var VC = 2262 Pass
20.0.5 Analysis: VA VA[2265] 2210 2340 Pass
20.0.6 Analysis: VB VB[2261] 2210 2340 Pass
20.0.7 Analysis: VC VC[2262] 2210 2340 Pass
20.1.3 TestSW: [ADC_PA1] sense B 2097 1996[VB] 2096[VB] Fail
20.1.2 TestSW: [ADC_PA0] sense A 2436 2430[VA] 2530[VA] Pass
20.1.1 EL1.2: Ověření proudu na zátěži -> Current? 4,989855 4,7 5,3 Pass
20.1 NZ3.1: Měření napětí: Zkrat? 28,00851 > 27,9 Pass
20.2 NZ3.1: Měření proudu: Kontrola odběru 0,03767969 < 0,06 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (1)
DateValueMinMax
2026-07-09 15:00 1.047 10