Serial C00000506

Tests3
Approved1
Failures2

Tests over time

Test history

DateMeasurement IDID recordArticleResult
2026-02-23 11:50 53823 639074442243717601-9449 S0003591 Fail View
2026-02-23 11:51 53824 639074442700018422-4872 S0003591 Fail View
2026-02-23 11:53 53825 639074443319467369-4684 S0003591 Pass View

Test 53824

Result
Fail
Date
2026-02-23 11:51
Article
S0003591
ID record
639074442700018422-4872
ID production
Temperature
Humidity
Test duration
26
Error ID
218
Error text
TestSW: test oscilátoru ON

Measurement lines

StepNameValueMinMaxResult
1.1.1 DMM: Měření odporu: R1 (TP5/TP4) 5607.66465 5320 5880 Pass
1.1.2 DMM: Měření odporu: R2 (TP5/TP6) 998.235431 950 1050 Pass
1.2.1 DMM: Měření odporu: F1 (TP9/TP8) 0.636850548 < 2 Pass
1.2.2 DMM: Měření odporu: F2 (TP10/TP11) 0.418288762 < 2.5 Pass
1.2.3 DMM: Měření odporu: R3+R4 (TP10/TP8) 1435054.93 120000 1540000 Pass
2.2.1 DMM: Měření napětí: +5V StepDown Output (TP2/TP13) 5.17712958 4 6 Pass
2.2.2 DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) 3.29131493 2.64 3.96 Pass
2.2.3 DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) 3.28360532 2.64 3.96 Pass
2.2.4 DMM: Měření napětí: +3V3 VDDA (TP2/TP22) 3.28209626 2.64 3.96 Pass
2.2.5 DMM: Měření napětí: +1V8 Audio (TP2/TP24) 1.79980585 1.44 2.16 Pass
2.2.6 DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) 11.986444 9.6 14.4 Pass
2.3.1 AC1: Měření proudu: Kontrola odběru 0.00903827 < 0.12 Pass
2.3.2 DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) 11.9583272 11.4 12.6 Pass

Measurements over time

Hover for exact values · drag to zoom · double-click to reset

Readings (3)
DateValueMinMax
2026-02-23 11:50 998.259 950 1050
2026-02-23 11:51 998.235 950 1050
2026-02-23 11:53 998.223 950 1050