Serial C00000455
Tests5
Approved1
Failures4
Tests over time
Test history
| Date | Measurement ID | ID record | Article | Result | |
|---|---|---|---|---|---|
| 2026-02-23 09:46 | 53743 | 639074367558220841-9332 | S0003591 | Fail | View |
| 2026-02-23 09:47 | 53744 | 639074368046299300-5952 | S0003591 | Fail | View |
| 2026-02-23 09:48 | 53745 | 639074368711119218-9975 | S0003591 | Fail | View |
| 2026-02-23 09:49 | 53746 | 639074369335079980-2014 | S0003591 | Fail | View |
| 2026-02-23 09:51 | 53747 | 639074370142034271-4625 | S0003591 | Pass | View |
Test 53743
- Result
- Fail
- Date
- 2026-02-23 09:46
- Article
- S0003591
- ID record
- 639074367558220841-9332
- ID production
- Temperature
- Humidity
- Test duration
- 32
- Error ID
- 295
- Error text
- DMM: Měření zkratu: RE5 - NC (TP43/TP42) SHORT
Measurement lines
| Step | Name | Value | Min | Max | Result |
|---|---|---|---|---|---|
| 1.1.2 | DMM: Měření odporu: R2 (TP5/TP6) | 1001.24188 | 950 | 1050 | Pass |
| 1.1.1 | DMM: Měření odporu: R1 (TP5/TP4) | 5604.21367 | 5320 | 5880 | Pass |
| 1.2.1 | DMM: Měření odporu: F1 (TP9/TP8) | 0.425196251 | < | 2 | Pass |
| 1.2.2 | DMM: Měření odporu: F2 (TP10/TP11) | 0.733167225 | < | 2.5 | Pass |
| 1.2.3 | DMM: Měření odporu: R3+R4 (TP10/TP8) | 687909.122 | 120000 | 1540000 | Pass |
| 2.2.1 | DMM: Měření napětí: +5V StepDown Output (TP2/TP13) | 5.15952079 | 4 | 6 | Pass |
| 2.2.2 | DMM: Měření napětí: +3V3 LDO Output (TP2/TP14) | 3.29350303 | 2.64 | 3.96 | Pass |
| 2.2.3 | DMM: Měření napětí: +3V3 Modem AVCC (TP2/TP16) | 3.28689541 | 2.64 | 3.96 | Pass |
| 2.2.4 | DMM: Měření napětí: +3V3 VDDA (TP2/TP22) | 3.29220972 | 2.64 | 3.96 | Pass |
| 2.2.5 | DMM: Měření napětí: +1V8 Audio (TP2/TP24) | 1.79778028 | 1.44 | 2.16 | Pass |
| 2.2.6 | DMM: Měření napětí: +12V Bed Interface Power (TP2/TP28) | 11.9937742 | 9.6 | 14.4 | Pass |
| 2.3.1 | AC1: Měření proudu: Kontrola odběru | 0.0220172 | < | 0.12 | Pass |
| 2.3.2 | DMM: Měření napětí: +12V ACDC měnič (TP2/TP12) | 11.9137954 | 11.4 | 12.6 | Pass |
| 3.2.1 | DMM: Měření frekvence: 1kHz (TP2/TP17) | 1000.01512 | 999.8 | 1000.2 | Pass |
| 3.3.1 | DMM: Měření proudu: LEDR (TP25/TP27) | 2.85449251E-07 | < | 0.0005 | Pass |
| 3.3.2 | DMM: Měření proudu: LEDR (TP25/TP27) | 0.0339963262 | 0.015 | 0.05 | Pass |
| 3.3.3 | DMM: Měření proudu: LEDR (TP25/TP27) | -2.06921425E-08 | < | 0.0005 | Pass |
| 3.3.4 | DMM: Měření proudu: LEDG (TP25/TP27) | -1.64868493E-08 | < | 0.0005 | Pass |
| 3.3.5 | DMM: Měření proudu: LEDG (TP25/TP27) | 0.0343713258 | 0.015 | 0.05 | Pass |
| 3.3.6 | DMM: Měření proudu: LEDG (TP25/TP27) | -1.88982423E-08 | < | 0.0005 | Pass |
| 3.4.1 | DMM: Měření proudu: (TP29/TP27) | 0.00097521498 | < | 0.0013 | Pass |
| 3.4.2 | DMM: Měření proudu: (TP34/TP27) | 0.000976006039 | < | 0.0013 | Pass |
| 3.5.1 | NZ3.1: Měření proudu: Kontrola odběru | 0.005094747 | < | 0.01 | Pass |
| 3.5.2 | NZ3.1: Měření proudu: Kontrola odběru | 0.005080048 | < | 0.01 | Pass |
| 3.6.1 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) OPEN | 9.9E+37 | > | 1000000 | Pass |
| 3.6.2 | DMM: Měření zkratu: RE5 - NC (TP43/TP42) SHORT | 1.48173332 | < | 1 | Fail |
Measurements over time
Hover for exact values · drag to zoom · double-click to reset
Readings (5)
| Date | Value | Min | Max |
|---|---|---|---|
| 2026-02-23 09:46 | 1001.242 | 950 | 1050 |
| 2026-02-23 09:47 | 1001.191 | 950 | 1050 |
| 2026-02-23 09:48 | 1001.166 | 950 | 1050 |
| 2026-02-23 09:49 | 1001.15 | 950 | 1050 |
| 2026-02-23 09:51 | 1001.131 | 950 | 1050 |